Matrix-shimmed ion cyclotron resonance ion trap simultaneously optimized for excitation, detection, quadrupolar axialization, and trapping

被引:23
作者
Jackson, GS [1 ]
White, FM [1 ]
Guan, SH [1 ]
Marshall, AG [1 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Ctr Interdisciplinary Magnet Resonance, Tallahassee, FL 32310 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(99)00048-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A different symmetry is required to optimize each of the three most common Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) electric potentials in a Penning (ICR) ion trap: one-dimensional dipolar ac for excitation (or detection), two-dimensional azimuthal quadrupolar ac excitation for ion axialization, and three-dimensional axial quadrupolar de potential for ion axial confinement (trapping). Since no single trap shape simultaneously optimizes all three potentials, many trap configurations have been proposed to optimize the tradeoffs between the three requirements for a particular experiment. A more general approach is to divide each electrode into small segments and then apply the appropriate potential to each segment. Here, we extend segmentation to its logical extreme, by constructing a "matrix-shimmed" trap consisting of a cubic trap, with each side divided into a 5 x 5 grid of electrodes for a total of 150 electrodes. Theoretically, only 48 independent voltages need be applied to these 150 electrodes to generate all three desired electric potential fields simultaneously. In practice, it is more convenient to employ 63 independent voltages due to construction constraints. Resistive networks generate the potentials required for optimal quadrupolar trapping and quadrupolar excitation. To avoid resistive loss of excitation amplitude and detected signal, dipolar excitation/detection voltages are generated with a capacitive network. Theoretical Simion 6.0 simulations confirm the achievement of near-ideal potentials of all three types simultaneously. From a proof-of-principle working model, several experimental benefits are demonstrated, and proposed future improvements are discussed. (C) 1999 American Society for Mass Spectrometry.
引用
收藏
页码:759 / 769
页数:11
相关论文
共 50 条
[1]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[2]   ELIMINATION OF AXIAL EJECTION DURING EXCITATION WITH A CAPACITIVELY COUPLED OPEN TRAPPED-ION CELL FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :177-180
[3]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[4]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518
[5]   AN OFF-CENTER CUBIC ION-TRAP FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, R ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 133 (01) :29-38
[6]  
DAHL DA, 1988, SIMION 3D VERSION 6
[7]   ZETA-AXIS OSCILLATION SIDEBANDS IN FT ICR MASS-SPECTRA [J].
DELONG, SE ;
MITCHELL, DW ;
CHERNIAK, DJ ;
HARRISON, TM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 91 (03) :273-282
[8]   DYNAMIC ION TRAPPING FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY - SIMULTANEOUS POSITIVE-ION AND NEGATIVE-ION DETECTION [J].
GORSHKOV, MV ;
GUAN, SH ;
MARSHALL, AG .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (03) :166-172
[9]   COMPREHENSIVE THEORY OF THE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SIGNAL FOR ALL ION TRAP GEOMETRIES [J].
GROSSHANS, PB ;
SHIELDS, PJ ;
MARSHALL, AG .
JOURNAL OF CHEMICAL PHYSICS, 1991, 94 (08) :5341-5352
[10]   THEORY OF ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY - RESONANT EXCITATION AND RADIAL EJECTION IN ORTHORHOMBIC AND CYLINDRICAL ION TRAPS [J].
GROSSHANS, PB ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 100 :347-379