The performance of four different corneal topographers on normal human corneas and its impact on orthokeratology lens fitting

被引:76
作者
Cho, P [1 ]
Lam, AKC [1 ]
Mountford, J [1 ]
Ng, L [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Optometry & Radiog, Ctr Myopia Res, Kowloon, Hong Kong, Peoples R China
关键词
corneal topography; apical radius; eccentricity; elevation; Chinese;
D O I
10.1097/00006324-200203000-00012
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose. To evaluate the performances of Humphrey Atlas 991, Orbscan II, Dicon CT200 Medmont E300 on young Chinese adults. Methods. Three sets of corneal topography measurements were obtained from each topographer from 22 subjects-two sets by the same examiner and one set by another examiner on the same day. Results. There were no significant within-examiner and between-examiner differences for any of the parameters tested for each topographer. However, only the repeatability and reproducibility (of apical radius[R-o], eccentricity, and elevation) of the Humphrey and Medmont were good. There was no statistically significant between-topographer difference in R-o, but significant differences in eccentricity and elevation values were found. The number of repeated readings that should be taken for a precision of 2 mum (elevation) were 12 for the Humphrey and 2 for the Medmont. Conclusions. The performance of both the Humphrey and the Medmont was very good. R-o and eccentricity values of different topographers cannot be used interchangeably, but the agreement in elevation values was good for these topographers. The number of repeated readings required for maximum precision varies with the topographer used, and they are not interchangeable.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 27 条
[1]
[Anonymous], FDN CLIN RES APPL PR
[2]
Ray tracing through non-spherical surfaces [J].
Baker, TY .
PROCEEDINGS OF THE PHYSICAL SOCIETY, 1943, 55 :0361-0364
[3]
BENENTT AG, 1988, OPTOMETRY TODAY, V4, P33
[4]
Bennett A. G., 1988, OPTOMETRY TODAY, V28, P140
[5]
Bennett A.G., 1988, OPTOM TODAY, V28, P238
[6]
BENNETT AG, 1988, OPTOMETRY TODAY, V2, P38
[7]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]
CAROLINE PJ, 2001, CONTACT LENS ANTERIO, V4, P41
[9]
COHEN KL, 1994, ISRK 1994 PREAM AC O, P100
[10]
Randomized bilateral comparison of excimer laser in situ keratomileusis and photorefractive keratectomy for 2.50 to 8.00 diopters of myopia [J].
El-Maghraby, A ;
Salah, T ;
Waring, GO ;
Klyce, S ;
Ibrahim, O .
OPHTHALMOLOGY, 1999, 106 (03) :447-457