Comparison of three generations of electron beam tomography on image noise and reproducibility, a phantom study

被引:9
作者
Chau, Alex
Gopal, Ambarish
Mao, SongShou
Tseng, Philip H.
Fischer, Hans
Budoff, Matthew J.
机构
[1] Harbor ULCA Res & Educ Inst, Dept Med, Div Cardiol, Torrance, CA 90502 USA
[2] Harbor ULCA Res & Educ Inst, Dept Radiol, Torrance, CA 90502 USA
关键词
CT Electron beam computed tomography; reproducibility; collimation; computed tomography; cardiac CT;
D O I
10.1097/01.rli.0000209664.29849.b7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The detection of coronary artery calcification (CAC) using the electron beam tomography (EBT) scanner provides a noninvasive indicator for coronary artery disease (CAD). Physicians interested in preventative medicine also are using this modality to track atherosclerosis over time. Two new iterations of the EBT scanner have been introduced. We sought to evaluate the image quality of each machine to examine whether patients scanned on a previous model would have similar image quality and results to those scanned on the newest scanner. Methods: This study used the C-150 XP, C300, and the e-Speed EBT scanners in high-resolution volume mode. A cork chest phantom was constructed for use as a human chest. A mixture of calcium phosphate, cornstarch and glue was placed inside the wells to simulate coronary calcium. The foci masses were 3, 5, 7, 10, 15, 20, 40, 60, 80, 100, and 200 mg (calcium mass), which provided the 5 5 foci of different masses and densities to simulate coronary calcium in the chest phantom. Each phantom was scanned multiple times, using both 1.5- and 3-mm slice thickness and table collimation settings with each scanner. Results: There were no statistical differences found between the 1.5-min and 3.0-mm slice thickness calcium foci scores (Agatston & volumetric) for all 3 EBT scanners. The C-150 XP scanner had a variability of 6.01% between 1.5-mm and 3.0-mm slice thickness. Analysis by t test revealed that the mean noise value of C-150 XP was significantly higher than the C300, e-Speed (50 milliseconds), and e-Speed (100 milliseconds) with P values of 0.001, 0.025, and 0.001, respectively. Comparison of 1.5-mm versus 3.0-mm slice thickness noise value showed a significant difference only for the C-150 XP scanner (P < 0.05). Conclusions: The use of the 3 EBT scanners in longitudinal studies of patients coronary calcium score is feasible to obtain similar calcium score values. The C-150 XP has the greatest noise effect in comparison to the C300 and e-Speed scanners. Improved image
引用
收藏
页码:522 / 526
页数:5
相关论文
共 26 条
[1]   Influence of lipid-lowering therapy on the progression of coronary artery calcification - A prospective evaluation [J].
Achenbach, S ;
Ropers, D ;
Pohle, K ;
Leber, A ;
Thilo, C ;
Knez, A ;
Menendez, T ;
Maeffert, R ;
Kusus, M ;
Regenfus, M ;
Bickel, A ;
Haberl, R ;
Steinbeck, G ;
Moshage, W ;
Daniel, WG .
CIRCULATION, 2002, 106 (09) :1077-1082
[2]   Prediction of coronary events with electron beam computed tomography [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
Newstein, D ;
Guerci, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1253-1260
[3]   Electron beam computed tomography: Screening for coronary artery disease [J].
Budoff, MJ ;
Brundage, BH .
CLINICAL CARDIOLOGY, 1999, 22 (09) :554-558
[4]   Rates of progression of coronary calcium by electron beam tomography [J].
Budoff, MJ ;
Lane, KL ;
Bakhsheshi, H ;
Mao, S ;
Grassmann, BO ;
Friedman, BC ;
Brundage, BH .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (01) :8-11
[5]   Methodology for improved detection of coronary stenoses with computed tomographic angiography [J].
Budoff, MJ ;
Lu, B ;
Shinbane, JS ;
Chen, L ;
Child, J ;
Carson, S ;
Mao, SS .
AMERICAN HEART JOURNAL, 2004, 148 (06) :1085-1090
[6]   Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: A multicenter study [J].
Budoff, MJ ;
Georgiou, D ;
Brody, A ;
Agatston, AS ;
Kennedy, J ;
Wolfkiel, C ;
Stanford, W ;
Shields, P ;
Lewis, RJ ;
Janowitz, WR ;
Rich, S ;
Brundage, BH .
CIRCULATION, 1996, 93 (05) :898-904
[7]  
BUDOFF MJ, 2005, IN PRESS ACAD RAD
[8]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[9]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[10]   Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation [J].
Gerber, TC ;
Stratmann, BP ;
Kuzo, RS ;
Kantor, B ;
Morin, RL .
INVESTIGATIVE RADIOLOGY, 2005, 40 (08) :556-563