Projection of the lumbar pedicle and its morphometric analysis

被引:89
作者
Ebraheim, NA [1 ]
Rollins, JR [1 ]
Xu, RM [1 ]
Yeasting, RA [1 ]
机构
[1] MED COLL OHIO,DEPT ANAT,TOLEDO,OH 43699
关键词
D O I
10.1097/00007632-199606010-00003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This study defined the projection point of the lumbar pedicle on its posterior aspect and its relation to a reliable landmark and reported pedicle dimensions based on 50 lumbar spines. Objectives. To establish the best starting point for a pedicle screw for passing the screw down the center (axis) of the pedicle; to describe quantitatively the relations of the pedicle projection point to a reliable landmark; and to evaluate the linear and angular dimensions of the lumbar pedicle. Summary of Background Data. Posterior transpedicular screw fixation has been most widely used for management of the unstable lumbar spine. Several studies of pedicular anatomy exist, but little quantitative data regarding the location of the lumbar pedicle axis for each level have been reported. Methods. Fifty dry lumar specimens (250 lumbar vertebrae) were obtained for study of the lumbar pedicle. Anatomic evaluation focused on determination of the projection point of the lumbar pedicle axis on the junction of the superior facet and the transverse process and measured the distance from the projection point to the midline of the transverse process for each level of the lumbar vertebrae. Pedicle dimensions, including linear and angular, also were measured. Results. Differences in dimension between men and women were not found to be statistically significant. The average distance from the projection point to the midline of the transverse process consistently changed from L1 to L5. Above L4, the projection point for men and women averaged 3.9 mm for L1, 2.8 mm for L2, and 1.4 mm for L3 superior to the midline of the transverse process, respectively. At L4, the projection point was close to the midline of the transverse process (0.5 mm inferior). At L5, the projection point was an average of 1.5 mm inferior to the midline of the transverse process. Conclusions. The average distance from the projection point of the lumbar pedicle axis to the midline of the transverse process consistently varied at different levels. This information may prove helpful in the placement of screws into the lumbar pedicle.
引用
收藏
页码:1296 / 1300
页数:5
相关论文
共 18 条
[1]   BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL [J].
ASHMAN, RB ;
GALPIN, RD ;
CORIN, JD ;
JOHNSTON, CE .
SPINE, 1989, 14 (12) :1398-1405
[2]   A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE [J].
BERRY, JL ;
MORAN, JM ;
BERG, WS ;
STEFFEE, AD .
SPINE, 1987, 12 (04) :362-367
[3]  
DICKMAN CA, 1994, SPINE, V19, pS2266
[4]  
HOU S, 1994, SPINE, V19, P1850
[5]  
Krag M H, 1988, J Spinal Disord, V1, P287
[6]   PLACEMENT OF TRANSPEDICULAR VERTEBRAL SCREWS CLOSE TO ANTERIOR VERTEBRAL CORTEX - DESCRIPTION OF METHODS [J].
KRAG, MH ;
VANHAL, ME ;
BEYNNON, BD .
SPINE, 1989, 14 (08) :879-883
[7]  
MAGERL FP, 1984, CLIN ORTHOPAEDICS, V189, P125
[8]   MORPHOMETRIC ANALYSIS OF THE THORACOLUMBAR AND LUMBAR PEDICLES, ANATOMO-RADIOLOGIC STUDY [J].
MARCHESI, D ;
SCHNEIDER, E ;
GLAUSER, P ;
AEBI, M .
SURGICAL AND RADIOLOGIC ANATOMY, 1988, 10 (04) :317-322
[9]   PROBLEMS AND SOLUTIONS OF PEDICLE SCREW PLATE FIXATION OF LUMBAR SPINE [J].
MATSUZAKI, H ;
TOKUHASHI, Y ;
MATSUMOTO, E ;
HOSHINO, M ;
KIUCHI, T ;
TORIYAMA, S .
SPINE, 1990, 15 (11) :1159-1165
[10]   ANATOMIC ANALYSIS OF PEDICLE CORTICAL AND CANCELLOUS DIAMETER AS RELATED TO SCREW SIZE [J].
MISENHIMER, GR ;
PEEK, RD ;
WILTSE, LL ;
ROTHMAN, SLG ;
WIDELL, EH .
SPINE, 1989, 14 (04) :367-372