How to Evaluate and Improve the Reliability of Power Doppler Ultrasonography for Assessing Enthesitis in Spondylarthritis

被引:71
作者
D'agostin, Maria Antonietta [2 ,3 ]
Aegerter, Philippe [2 ]
Jousse-Joulin, Sandrine [4 ]
Chary-Valckenaere, Isabelle
Lecoq, Bertrand [6 ]
Gaudin, Philippe [7 ]
Brault, Isabelle [5 ]
Schmitz, Jerome [1 ]
Dehaut, Francois-Xavier [1 ]
Le Parc, Jean-Marie
Breban, Maxime [2 ]
Landais, Paul [3 ]
机构
[1] CHU Timone, Marseille, France
[2] Univ Versailles St Quentin Yvelines, Ambroise Pare Hosp, AP HP, F-92400 Boulogne, France
[3] Univ Paris Descartes UPRES EA 4067, AP HP, Necker Hosp, Paris, France
[4] CHU La Cavale Blanche, Brest, France
[5] CHU Brabois, Vandoeuvre Les Nancy, France
[6] CHU Cote Nacre, Caen, France
[7] CHU Sud, Grenoble, France
来源
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH | 2009年 / 61卷 / 01期
关键词
ANKYLOSING-SPONDYLITIS; MUSCULOSKELETAL ULTRASONOGRAPHY; INTEROBSERVER RELIABILITY; ULTRASOUND; ENTHESOPATHY; INFLAMMATION; CRITERIA; CLASSIFICATION; ARTIFACTS; AGREEMENT;
D O I
10.1002/art.24369
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Objective. To evaluate and improve the reliability of power Doppler ultrasonography (PDUS) for detecting and scoring enthesitis in patients with spondylarthitis, using a 3-step procedure. Methods. In the first step, we evaluated the reliability of 5 sonographers by bilaterally scanning 5 entheses twice in 5 patients. In the second step, starting from disagreements observed during the first step, we established consensus guidelines. The sonographers' implementation was further evaluated in 2 reliability exercises: one on 60 PDUS enthesitis images and the other by scanning 5 new patients. In the third step, we performed a final reliability evaluation of 5 additional patients after 1 year. Kappa coefficients (K) as well as variance component analysis (VCA) and generalizability theory (GT) were used to assess reliability. Results. The initial intra- and interobserver reliability were poor, especially for detecting and scoring Doppler signal. VCA and GT showed that most variability was accounted for by interaction between sonographer and enthesis. Implementation of consensus guidelines was associated with a significant improvement in Doppler reliability between the first and second steps (mean interobserver K increased from 0.13 to 0.51 for binary Doppler scoring in patients; P < 0.005), which persisted in the third step (mean interobserver kappa = 0.57). The high GT coefficients reached in the last steps supported such improvement. Conclusion. The 3-step procedure used in this study to standardize PDUS technique was associated with a significant improvement in interobserver reliability for detecting enthesitis in spondylarthritis patients. Such an approach can be useful to standardize PDUS assessment of musculoskeletal disorders.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 45 条
[1]
A Sonographic Enthesitic Index of lower limbs is a valuable tool in the assessment of ankylosing spondylitis [J].
Alcalde, M. ;
Acebes, Juan C. ;
Cruz, M. ;
Gonzalez-Hombrado, L. ;
Herrero-Beaumont, G. ;
Sanchez-Pernaute, O. .
ANNALS OF THE RHEUMATIC DISEASES, 2007, 66 (08) :1015-1019
[2]
AMOR B, 1990, REV RHUM, V57, P85
[3]
All that glistens is not gold - Separating artefacts from true Doppler signals in rheumatological ultrasound [J].
Balint, Peter V. ;
Mandl, Peter ;
Kane, David .
ANNALS OF THE RHEUMATIC DISEASES, 2008, 67 (02) :141-142
[4]
Ultrasonography of entheseal insertions in the lower limb in spondyloarthropathy [J].
Balint, PV ;
Kane, D ;
Wilson, H ;
McInnes, IB ;
Sturrock, RD .
ANNALS OF THE RHEUMATIC DISEASES, 2002, 61 (10) :905-910
[5]
BALL J, 1983, BRIT J RHEUMATOL, V22, P25
[6]
[7]
Magnetic resonance imaging examinations of the spine in patients with Ankylosing spondylitis before and after therapy with the tumor necrosis factor α receptor fusion protein etanercept [J].
Baraliakos, X ;
Davis, J ;
Tsuji, W ;
Braun, J .
ARTHRITIS AND RHEUMATISM, 2005, 52 (04) :1216-1223
[8]
Inflammation in ankylosing spondylitis:: a systematic description of the extent and frequency of acute spinal changes using magnetic resonance imaging [J].
Baraliakos, X ;
Landewé, R ;
Hermann, KG ;
Listing, J ;
Golder, W ;
Brandt, J ;
Rudwaleit, M ;
Bollow, M ;
Sieper, J ;
van der Heijde, D ;
Braun, J .
ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 (05) :730-734
[9]
Assessment of acute spinal inflammation in patients with ankylosing spondylitis by magnetic resonance imaging:: a comparison between contrast enhanced T1 and short tau inversion recovery (STIR) sequences [J].
Baraliakos, X ;
Hermann, KGA ;
Landewé, R ;
Listing, J ;
Golder, W ;
Brandt, J ;
Rudwaleit, M ;
Bollow, M ;
Sieper, J ;
van der Heijde, D ;
Braun, J .
ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 (08) :1141-1144
[10]
The challenges of integrating ultrasonography into routine rheumatology practice: addressing the needs of clinical rheumatologists [J].
Brown, A. K. ;
Roberts, T. E. ;
Wakefield, R. J. ;
Karim, Z. ;
Hensor, E. ;
O'Connor, P. J. ;
Emery, P. .
RHEUMATOLOGY, 2007, 46 (05) :821-829