Linearity and quadrupolarity of tetragonal and cylindrical penning traps of arbitrary length-to-width ratio

被引:17
作者
Jackson, GS [1 ]
Canterbury, JD [1 ]
Guan, SH [1 ]
Marshall, AG [1 ]
机构
[1] FLORIDA STATE UNIV,NATL HIGH MAGNET FIELD LAB,ION CYCLOTRON RESONANCE PROGRAM,TALLAHASSEE,FL 32310
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(96)00232-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The two most popular Penning traps in use for Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry are tetragonal (i.e., orthorhombic with square cross section) and cylindrical. Here we compare tetragonal and cylindrical traps as a function of aspect (length-to-width) ratio and position within the trap, by comparing the numerically computed (from Simion 6.0) electric potential field of a given trap relative to each of three idealized potentials required for ET-ICR experiments: dipolar one-dimensional potential for alternating current (ac) excitation/detection of cyclotron motion, azimuthal two-dimensional quadrupolar potential for ac excitation for ion axialization, and axial three-dimensional quadrupolar potential for direct current axial confinement of ions. Our numerically computed results agree well with those previously derived analytically. The numerical approach provides a simpler and more accessible means for analyzing the aforementioned potentials. Moreover, the numerical approach (unlike the analytical approach) readily extends to traps of lower even when analytical solutions are available, the numerical method presented here is complementary, since it provides a useful check on the validity of the derived equations. (C) 1997 American Society for Mass Spectrometry.
引用
收藏
页码:283 / 293
页数:11
相关论文
共 50 条
[1]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[2]   ELIMINATION OF AXIAL EJECTION DURING EXCITATION WITH A CAPACITIVELY COUPLED OPEN TRAPPED-ION CELL FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :177-180
[3]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[4]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518
[5]   ULTRAHIGH-RESOLUTION MATRIX-ASSISTED LASER-DESORPTION IONIZATION OF SMALL PROTEINS BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CASTORO, JA ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2621-2627
[6]  
Comisarow M. B., 1980, ADV MASS SPECTROM B, V8B, P1698
[7]   CUBIC TRAPPED-ION CELL FOR ION-CYCLOTRON RESONANCE [J].
COMISAROW, MB .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1981, 37 (02) :251-257
[9]  
COMISAROW MB, 1976, Patent No. 3937955
[10]  
COMISAROW MB, 1982, ION CYCLOTRON RESONA, V2, P484