Improvement of the image quality of T1-weighted anatomical brain scans

被引:31
作者
Howarth, C [1 ]
Hutton, C [1 ]
Deichmann, R [1 ]
机构
[1] Inst Neurol, Wellcome Dept Imaging Neurosci, London WC1N 3BG, England
基金
英国惠康基金;
关键词
structural imaging; anatomical imaging; movement artefact; MDEFT; signal dropout; fat suppression; bandwidth;
D O I
10.1016/j.neuroimage.2005.08.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
T1-weighted anatomical brain scans are routinely used in neuroimaging studies, for example, as anatomical reference for functional data and in brain morphometry studies. Subject motion can degrade the quality of these images. An additional problem is the occurrence of signal dropouts in the case of long echo times and low receiver bandwidths. These problems are addressed in two different studies. In the first study, it is shown that the high scalp signal, which results typical ringing artefact in the from the low T1 value of fat, may cause a presence of head motion. This problem may be enhanced if phased array coils are used for signal reception due to their increased sensitivity in the peripheral head regions. It is shown that this artefact can be avoided by combining certain fat suppression techniques that reduce the scalp signal. In the second study, it is shown that signal dropout affects mainly the orbitufrontal cortex and the temporal lobes, and that a bandwidth of 100 Hz/pixel should be chosen for the investigation of these areas to avoid signal losses while maintaining an acceptable signal-to-noise ratio. Experimental results are based on the MDEFT sequence but can be applied to other T1-weighted sequences like FLASH and MP-RAGE. Furthermore, the presented methods for improving the image quality can be combined with other artefact reduction techniques. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:930 / 937
页数:8
相关论文
共 23 条
[1]   Multimodal image coregistration and partitioning - A unified framework [J].
Ashburner, J ;
Friston, K .
NEUROIMAGE, 1997, 6 (03) :209-217
[2]   Voxel-based morphometry - The methods [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2000, 11 (06) :805-821
[3]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[4]   Coil-based artifact reduction [J].
Atkinson, D ;
Larkman, DJ ;
Batchelor, PG ;
Hill, DLG ;
Hajnal, JV .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :825-830
[5]  
Atkinson D, 1999, MAGNET RESON MED, V41, P163, DOI 10.1002/(SICI)1522-2594(199901)41:1<163::AID-MRM23>3.0.CO
[6]  
2-9
[7]   INVIVO NUCLEAR MAGNETIC-RESONANCE CHEMICAL-SHIFT IMAGING BY SELECTIVE IRRADIATION [J].
BOTTOMLEY, PA ;
FOSTER, TH ;
LEUE, WM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1984, 81 (21) :6856-6860
[8]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857
[9]   Optimization of 3-D MP-RAGE sequences for structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Josephs, O ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2000, 12 (01) :112-127
[10]   Optimized RF excitation for anatomical brain imaging of the occipital lobe using the 3D MDEFT sequence and a surface transmit coil [J].
Deichmann, R .