Fatigue induced changes in conical implant-abutment connections

被引:65
作者
Blum, Kai [1 ]
Wiest, Wolfram [2 ]
Fella, Christian [2 ]
Balles, Andreas [2 ]
Dittmann, Jonas [2 ]
Rack, Alexander [3 ]
Maier, Dominik [1 ]
Thomann, Ralf [4 ]
Spies, Benedikt Christopher [1 ]
Kohal, Ralf Joachim [1 ]
Zabler, Simon [2 ]
Nelson, Katja [1 ]
机构
[1] Univ Freiburg Klinikum, Klin MKG Chirurg, D-79106 Freiburg, Germany
[2] Univ Wurzburg, Lehrstuhl Rontgenmikroskopie, D-97074 Wurzburg, Germany
[3] European Synchrotron Radiat Facil, Xray Imaging Grp, F-38043 Grenoble, France
[4] FMF Freiburger Mat Forschungzentrum, D-79104 Freiburg, Germany
关键词
Dental implants; Titanium; Deformation; Fatigue induced; IAC; Stability; Ankylos; Astra Tech; Nobel Active; Bone level; SYNCHROTRON-BASED RADIOGRAPHY; IN-VITRO EVALUATION; COMPLICATION RATES; DENTAL IMPLANTS; PERI-IMPLANTITIS; TITANIUM-ALLOYS; INTERFACE; JOINT; RESISTANCE; BONE;
D O I
10.1016/j.dental.2015.09.004
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Objectives. Based on the current lack of data and understanding of the wear behavior of dental two-piece implants, this study aims for evaluating the microgap formation and wear pattern of different implants in the course of cyclic loading. Methods. Several implant systems with different conical implant-abutment interfaces were purchased. The implants were first evaluated using synchrotron X-ray high-resolution radiography (SRX) and scanning electron microscopy (SEM). The implant-abutment assemblies were then subjected to cyclic loading at 98 N and their microgap was evaluated after 100,000, 200,000 and 1 million cycles using SRX, synchrotron micro-tomography (mu CT). Wear mechanisms of the implant-abutment connection (IAC) after 200,000 cycles and 1 million cycles were further characterized using SEM. Results. All implants exhibit a microgap between the implant and abutment prior to loading. The gap size increased with cyclic loading with its changes being significantly higher within the first 200,000 cycles. Wear was seen in all implants regardless of their interface design. The wear pattern comprised adhesive wear and fretting. Wear behavior changed when a different mounting medium was used (brass vs. polymer). Significance. A micromotion of the abutment during cyclic loading can induce wear and wear particles in conical dental implant systems. This feature accompanied with the formation of a microgap at the IAC is highly relevant for the longevity of the implants. (C) 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1415 / 1426
页数:12
相关论文
共 44 条
[1]
Dental Implants with Conical Implant-Abutment Interface: Influence of the Conical Angle Difference on the Mechanical Behavior of the Implant [J].
Aguirrebeitia, Josu ;
Abasolo, Mikel ;
Vallejo, Javier ;
Ansola, Ruben .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) :E72-E82
[2]
Banhart J., 2008, ADV TOMOGRAPHIC METH
[3]
Binon PP, 2000, INT J ORAL MAX IMPL, V15, P76
[4]
Bozini T, 2011, INT J ORAL MAX IMPL, V26, P304
[5]
Canullo L, 2014, CLIN ORAL IMPLANTS R
[6]
A Pilot Study of Joint Stability at the Zirconium or Titanium Abutment/Titanium Implant Interface [J].
Cavusoglu, Yeliz ;
Akca, Kivanc ;
Gurbuz, Riza ;
Cehreli, Murat Cavit .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) :338-343
[7]
Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant:: influence of abutment design [J].
Çehreli, MC ;
Akça, K ;
Iplikçioglu, H ;
Sahin, S .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :459-465
[8]
Cumulative survival rate and complication rates of single-tooth implant; focused on the coronal fracture of fixture in the internal connection implant [J].
Cha, H. -S. ;
Kim, Y. -S. ;
Jeon, J. -H. ;
Lee, J. -H. .
JOURNAL OF ORAL REHABILITATION, 2013, 40 (08) :595-602
[9]
Davis JR, 2001, SURFACE ENG CORROSIO
[10]
Derks J., 2014, J CLIN PERIODONTOL