Quantitative determination of cholesterol in lipoprotein fractions by electrophoresis

被引:24
作者
Contois, JH [1 ]
Gillmor, RG
Moore, RE
Contois, LRW
Macer, JL
Wu, AHB
机构
[1] Hartford Hosp, Dept Pathol & Lab Med, Div Clin Chem, Hartford, CT 06102 USA
[2] Hartford Hosp, Cholesterol Management Ctr, Hartford, CT 06102 USA
[3] Hartford Hosp, Dept Cardiol, Hartford, CT 06102 USA
关键词
cholesterol; lipoprotein electrophoresis; very low density lipoproteins; low density lipoproteins; high density lipoproteins; lipoprotein(a);
D O I
10.1016/S0009-8981(98)00186-7
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The Helena REP cholesterol profile system (Helena Laboratories, Beaumont, TX) separates VLDL, LDL, HDL and Lp(a) by agarose gel electrophoresis, and quantitates cholesterol by enzymatic staining and densitometry. We compared results by electrophoresis to combined ultracentrifugation/precipitation (beta-quantification, BQ) for VLDL, LDL, and HDL cholesterol and to immunonephelometry for Lp(a) mass (Behring Diagnostics, Westwood, MA) in serum from 64 patients with a variety of lipid disorders. There was good agreement between methods, with a mean bias of -0.19 (-7.3), 0.09 (3.5), and 0.09 (3.4) mmol/l (mg/dl) for VLDL, HDL, and LDL cholesterol for electrophoresis vs. BQ. These differences were significant for HDL and VLDL cholesterol (P < 0.001), but not for LDL cholesterol measurement (P > 0.05). There was also good correlation between methods with coefficients of 0.83, 0.92, 0.91, and 0.97 for VLDL, HDL, Lp(a), and LDL, respectively. Our data indicate that this method can accurately and precisely measure LDL cholesterol directly in fresh serum from patients with a wide range of triglyceride values. However, HDL cholesterol measurement did not meet NCEP guidelines for precision and accuracy. Also, the poor resolution of VLDL and LDL in some specimens is a concern. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 20 条
[1]  
BACHORIK PS, 1995, CLIN CHEM, V41, P1414
[2]  
BELCHER JD, 1994, LABORATORY MEASUREME, P107
[3]  
CHESLER R, 1995, CLIN CHEM, V41, pS141
[4]  
CLEEMAN JI, 1988, ARCH INTERN MED, V148, P36, DOI 10.1001/archinte.148.1.36
[5]   Plasma lipoprotein(a) distribution in the Framingham Offspring Study as determined with a commercially available immunoturbidimetric assay [J].
Contois, JH ;
LammiKeefe, CJ ;
Vogel, S ;
McNamara, JR ;
Wilson, PWF ;
Massov, T ;
Schaefer, EJ .
CLINICA CHIMICA ACTA, 1996, 253 (1-2) :21-35
[6]  
COSTELLO R, 1995, CLIN CHEM, V41, pS143
[7]  
GRUNDY SM, 1993, JAMA-J AM MED ASSOC, V269, P3015, DOI 10.1001/jama.269.23.3015
[8]  
JAILAL I, 1995, AM J CLIN PATHOL, V104, P76
[9]  
LAWSON GM, 1995, CLIN CHEM, V41, pS135
[10]  
LEVINE DM, 1994, CLIN CHEM, V40, P1602