Nickel/Copper nanoparticles modified TiO2 nanotubes for non-enzymatic glucose biosensors

被引:169
作者
Li, Xiaoling [2 ]
Yao, Jianyu [2 ]
Liu, Feila [2 ]
He, Huichao [2 ]
Zhou, Ming [2 ]
Mao, Nan [2 ]
Xiao, Peng [1 ,2 ]
Zhang, Yunhuai [2 ]
机构
[1] Chongqing Univ, Coll Phys, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Coll Chem Engn, Chongqing 400044, Peoples R China
关键词
TiO2 nanotube arrays; Ni-Cu nanoparticles; Non-enzymatic glucose biosensor; Electrocatalysis; CU-NI; ELECTROCATALYTIC OXIDATION; ALLOY ELECTRODES; NICKEL-COPPER; SENSOR; PLATINUM; NANOWIRE; CATALYSTS; FILMS;
D O I
10.1016/j.snb.2013.02.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly ordered TiO2 nanotube arrays (TiO2NTs) evenly modified by Ni-Cu nanoparticles were successfully prepared by potential step method. Their morphologies, structures, and alloy composition were characterized by FESEM, XRD and EDS, respectively. The as-prepared Ni-Cu/TiO2NTs electrodes were employed for non-enzymatic glucose detection in alkaline electrolyte and showed better electro-catalytic activity compared with Ni/TiO2NTs and Cu/TiO2NTs electrodes. Factors that affected the electrocatalysis of the electrodes were examined and optimized. Consequently, a sensitive amperometric electrode of glucose was achieved under 0.6V vs. Ag/AgCl with a high sensitivity (1590.9 mu A mM(-1) cm(-2)), low detection limit (5 mu M) and wide linear range from 10 mu M to 3.2 mM (R-2 = 0.993). Furthermore, the oxidable species such as ascorbic acid and uric acid showed no significant interference in determination of glucose. The experiment results revealed a very good reproducibility and high stability for the proposed Ni-Cu/TiO2NTs electrodes. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 45 条
[1]   Structure-to-property relationships in fuel cell catalyst supports: Correlation of surface chemistry and morphology with oxidation resistance of carbon blacks [J].
Artyushkova, Kateryna ;
Pylypenko, Svitlana ;
Dowlapalli, Madhu ;
Atanassov, Plamen .
JOURNAL OF POWER SOURCES, 2012, 214 :303-313
[2]   Effect of Ni content on the corrosion behavior of Cu-Ni alloys in neutral chloride solutions [J].
Badawy, WA ;
Ismail, KM ;
Fathi, AM .
ELECTROCHIMICA ACTA, 2005, 50 (18) :3603-3608
[3]   Nickel and Nickel-Based Nanoalloy Thin Films from Alcohol-Assisted Chemical Vapor Deposition [J].
Bahlawane, Naoufal ;
Premkumar, Peter Antony ;
Tian, Zhenyu ;
Hong, Xin ;
Qi, Fei ;
Kohse-Hoeinghaus, Katharina .
CHEMISTRY OF MATERIALS, 2010, 22 (01) :92-100
[4]   Pt-Pb nanowire array electrode for enzyme-free glucose detection [J].
Bai, Yu ;
Sun, Yingying ;
Sun, Changqing .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :579-585
[5]   Tailored Ni-Cu alloy hierarchical porous nanowire as a potential efficient catalyst for DMFCs [J].
Ding, Ruimin ;
Liu, Jinping ;
Jiang, Jian ;
Wu, Fei ;
Zhu, Jianhui ;
Huang, Xintang .
CATALYSIS SCIENCE & TECHNOLOGY, 2011, 1 (08) :1406-1411
[6]   Electrospun Co3O4 nanofibers for sensitive and selective glucose detection [J].
Ding, Yu ;
Wang, Ying ;
Su, Liang ;
Bellagamba, Michael ;
Zhang, Heng ;
Lei, Yu .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :542-548
[7]   A surface analytical examination of passive layers on Cu/Ni alloys .1. Alkaline solution [J].
Druska, P ;
Strehblow, HH ;
Golledge, S .
CORROSION SCIENCE, 1996, 38 (06) :835-851
[8]   Nonenzymatic glucose sensing based on deposited palladium nanoparticles on epoxy-silver electrodes [J].
Gutes, Albert ;
Carraro, Carlo ;
Maboudian, Roya .
ELECTROCHIMICA ACTA, 2011, 56 (17) :5855-5859
[9]  
GUZMAN RSS, 1978, J ELECTROCHEM SOC, V125, P1578
[10]   Electrochemical oxidation of glucose on single crystal and polycrystalline gold surfaces in phosphate buffer [J].
Hsiao, MW ;
Adzic, RR ;
Yeager, EB .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (03) :759-767