Modeling particle distribution and deposition in indoor environments with a new drift-flux model

被引:271
作者
Chen, FZ [1 ]
Yu, SCM [1 ]
Lai, ACK [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
computational fluid dynamics; drift-flux model; ventilation; indoor particles; mixing;
D O I
10.1016/j.atmosenv.2005.09.044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new drift-flux model for particle distribution and deposition in indoor environments is developed. Gravitational settling and deposition are examined thoroughly and the model is applied to simulate particle distribution and deposition in a ventilated model room. The turbulent airflow field is modeled with the renormalization group (RNG) k-epsilon turbulence model. For the particulate phase, the concentration field is divided into two regions, the core region and the concentration boundary layer. The concentration distribution in the core region is obtained by solving a three-dimensional particle transport equation. Deposition flux towards the wall is determined with a semi-empirical particle deposition model. With the feasibility of the proposed Eulerian model, the influences of the other deposition mechanisms can be captured easily into the model. The model is validated experimentally and a good agreement between numerical and experimental results is found. Inferring from the result, it shows that the well-mixed assumption cannot hold for coarse particles. The model presented in the current work provides an efficient and reliable tool for investigation of spatial and temporal particle concentration in enclosures and the result will be very useful for improving our current understanding of human exposure assessment. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:357 / 367
页数:11
相关论文
共 30 条
[1]   Using large eddy simulation to study particle motions in a room [J].
Béghein, C ;
Jiang, Y ;
Chen, QY .
INDOOR AIR, 2005, 15 (04) :281-290
[2]   An Eulerian model for particle deposition under electrostatic and turbulent conditions [J].
Chen, FZ ;
Lai, ACK .
JOURNAL OF AEROSOL SCIENCE, 2004, 35 (01) :47-62
[3]   COMPARISON OF DIFFERENT K-EPSILON MODELS FOR INDOOR AIR-FLOW COMPUTATIONS [J].
CHEN, Q .
NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 1995, 28 (03) :353-369
[4]   Three-dimensional analysis of airflow and contaminant particle transport in a partitioned enclosure [J].
Chung, KC .
BUILDING AND ENVIRONMENT, 1999, 34 (01) :7-17
[5]   Characterization of infectious aerosols in health care facilities: An aid to effective engineering controls and preventive strategies [J].
Cole, EC ;
Cook, CE .
AMERICAN JOURNAL OF INFECTION CONTROL, 1998, 26 (04) :453-464
[6]   THE COAGULATION AND DEPOSITION OF A STIRRED AEROSOL [J].
CORNER, J ;
PENDLEBURY, ED .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1951, 64 (380) :645-654
[7]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[8]   MIXING OF A POINT-SOURCE INDOOR POLLUTANT BY FORCED-CONVECTION [J].
DRESCHER, AC ;
LOBASCIO, C ;
GADGIL, AJ ;
NAZAROFF, WW .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1995, 5 (03) :204-214
[9]  
Etheridge D., 1996, Building ventilation: theory and measurement
[10]   ON THE MEASUREMENT OF PARTICLE CONCENTRATION NEAR A STAGNATION POINT [J].
HARDALUPAS, Y ;
TAYLOR, AMKP .
EXPERIMENTS IN FLUIDS, 1989, 8 (1-2) :113-118