Current control of a three-phase submerged arc ferrosilicon furnace

被引:35
作者
Hauksdóttir, AS
Gestsson, A
Vésteinsson, A
机构
[1] Univ Iceland, Dept Elect & Comp Engn, IS-107 Reykjavik, Iceland
[2] Univ Iceland, Engn Res Inst, Syst Engn Lab, IS-107 Reykjavik, Iceland
关键词
closed-loop process control; MIMO; decoupling; PI control;
D O I
10.1016/S0967-0661(01)00104-6
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Models of a 36 MW submerged are ferrosilicon (FeSi) furnace have been developed for the simulation and evaluation of different control schemes. The models developed, describing the present furnace controller, the electrode positioning equipment as well as the dynamics from the electrode positions to the electrode currents and the disturbance environment, effectively forming a FeSi furnace simulator, were then validated for two furnaces as well as for different operating ranges. In this paper, the validated simulator is used to evaluate the benefits of a decoupling controller compared to the present furnace controller which controls the current in each. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:457 / 463
页数:7
相关论文
共 14 条
[1]  
BARKER IJ, 1981, 2129 NAT I MET RANSB
[2]  
BARKER IJ, 1980, P 3 IFAC S AUT MIN M
[3]  
BRETON E, 1979, P 37 EL FURN C DETR
[4]  
De Waal A., 1992, P INFACON 6 CAP TOWN, V1, P247
[5]  
GESTSON A, 1997, KVS970501 U ICEL ENG
[6]  
GESTSSON A, 1995, 950701 U ICEL ENG RE
[7]  
GESTSSON A, 1994, THESIS U ICELAND
[8]   Submerged-arc ferrosilicon furnace simulator:: validation for different furnaces and operating ranges [J].
Hauksdóttir, AS ;
Gestsson, A ;
Vésteinsson, A .
CONTROL ENGINEERING PRACTICE, 1998, 6 (08) :1035-1042
[9]   SYSTEM-IDENTIFICATION OF A 3-PHASE SUBMERGED-ARC FERROSILICON FURNACE [J].
HAUKSDOTTIR, AS ;
SODERSTROM, T ;
THORFINNSSON, YP ;
GESTSSON, A .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 1995, 3 (04) :377-387
[10]  
HAUKSDOTTIR AS, 1996, P 13 IFAC WORLD C SA, P421