Many of the molecules involved in biological signaling processes are easily oxidized and have been monitored by electrochemical methods, Temporal response, spatial considerations, and sensitivity of the electrodes must be optimized for the specific biological application. To monitor exocytosis from single cells in culture, constant potential amperometry offers the best temporal resolution, and a low-noise picoammeter improves the detection limits. Smaller electrodes, with 1-mu m diameters, provided spatial resolution sufficient to identify the locations of release sites on the surface of single cells, For the study of neurotransmitter release in vivo, larger cylindrical microelectrodes are-advantageous because the secreted molecules come from multiple terminals near the electrode, and the greater amounts lead to a larger signal that emerges from the Johnson noise of the current amplifier. With this approach, dopamine release elicited by two electrical stimulus pulses at 10 Hz was detected with fast-scan cyclic voltammetry in vivo, Nafion-coated elliptical electrodes have previously been shown to be incapable of detecting such concentration changes without extensive signal averaging. In addition, we demonstrate that high-pass filtering (200 Hz) of cyclic voltammograms recorded at 300 V/s decreases the background current and digitization noise at these microelectrodes, leading to an improved signal, Also, high-pass filtering discriminated against ascorbic acid, DOPAC, and acidic pH changes, three common interferences in vivo.
引用
收藏
页码:3180 / 3186
页数:7
相关论文
共 53 条
[1]   ELECTROCOATING CARBON-FIBER MICROELECTRODES WITH NAFION IMPROVES SELECTIVITY FOR ELECTROACTIVE NEUROTRANSMITTERS [J].
BRAZELL, MP ;
KASSER, RJ ;
RENNER, KJ ;
FENG, J ;
MOGHADDAM, B ;
ADAMS, RN .
JOURNAL OF NEUROSCIENCE METHODS, 1987, 22 (02) :167-172
[2]   REAL-TIME MEASUREMENT OF TRANSMITTER RELEASE FROM SINGLE SYNAPTIC VESICLES [J].
BRUNS, D ;
JAHN, R .
NATURE, 1995, 377 (6544) :62-65
[3]  
CASS WA, 1995, J NEUROCHEM, V65, P201
[4]   NONLINEAR RELATIONSHIP BETWEEN IMPULSE FLOW, DOPAMINE RELEASE AND DOPAMINE ELIMINATION IN THE RAT-BRAIN IN-VIVO [J].
CHERGUI, K ;
SUAUDCHAGNY, MF ;
GONON, F .
NEUROSCIENCE, 1994, 62 (03) :641-645
[5]   DELAY IN VESICLE FUSION REVEALED BY ELECTROCHEMICAL MONITORING OF SINGLE SECRETORY EVENTS IN ADRENAL CHROMAFFIN CELLS [J].
CHOW, RH ;
VONRUDEN, L ;
NEHER, E .
NATURE, 1992, 356 (6364) :60-63
[7]   CONTINUOUS IN-VIVO MONITORING OF EVOKED DOPAMINE RELEASE IN THE RAT NUCLEUS-ACCUMBENS BY AMPEROMETRY [J].
DUGAST, C ;
SUAUDCHAGNY, MF ;
GONON, F .
NEUROSCIENCE, 1994, 62 (03) :647-654
[8]   DIRECT INVIVO MONITORING OF DOPAMINE RELEASED FROM 2 STRIATAL COMPARTMENTS IN THE RAT [J].
EWING, AG ;
BIGELOW, JC ;
WIGHTMAN, RM .
SCIENCE, 1983, 221 (4606) :169-171
[9]   PULSE VOLTAMMETRY WITH MICROVOLTAMMETRIC ELECTRODES [J].
EWING, AG ;
DAYTON, MA ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1842-1847
[10]   ELECTROCHEMICAL PRETREATMENT OF CARBON-FIBERS FOR INVIVO ELECTROCHEMISTRY - EFFECTS ON SENSITIVITY AND RESPONSE-TIME [J].
FENG, JX ;
BRAZELL, M ;
RENNER, K ;
KASSER, R ;
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1863-1867