Determination of melamine content in amino resins by near-infrared spectroscopy

被引:11
作者
Henriques, Ana [1 ]
Cruz, Paulo [2 ]
Ferra, Joao M. [2 ]
Martins, Jorge [1 ,3 ]
Magalhaes, Fernao D. [1 ]
Carvalho, Luisa H. [1 ,3 ]
机构
[1] Univ Porto, Fac Engn, Dept Engn Quim, LEPAE, P-4200465 Oporto, Portugal
[2] Ind Quim SA, Euroresinas, P-7520195 Sines, Portugal
[3] Inst Politecn Viseu, Dept Engn Madeiras, DEMad, P-3504510 Viseu, Portugal
关键词
UREA-FORMALDEHYDE RESINS; EMISSION;
D O I
10.1007/s00226-013-0547-6
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
Melamine-urea-formaldehyde resin production has increased in the last years due to low formaldehyde emissions and improved moisture resistance when applied on wood-based panels. Melamine is a relatively high-cost raw material in the resin formulation and has a significant effect on wood-based panel properties. It is important for industry to implement efficient quality control methods to determine melamine content in resins. The main objective of this work was to develop chemometric techniques for off-line monitoring of melamine content using near-infrared spectroscopy. The use of interval partial least squares regression allowed identifying the most interesting spectral ranges for analysis (4,400-4,800 and 5,200-5,600 cm(-1)) and the best preprocessing methods to use in the determination of this property. When the appropriate spectral range and preprocessing methods are selected, it is possible to obtain calibration models with high correlation coefficients.
引用
收藏
页码:939 / 948
页数:10
相关论文
共 22 条
  • [1] Variable selection in regression-a tutorial
    Andersen, C. M.
    Bro, R.
    [J]. JOURNAL OF CHEMOMETRICS, 2010, 24 (11-12) : 728 - 737
  • [2] Bjorsvik H., 2008, Handbook of Near-Infrared Analysis, VThird, P189
  • [3] Analysis of water in food by near infrared spectroscopy
    Büning-Pfaue, H
    [J]. FOOD CHEMISTRY, 2003, 82 (01) : 107 - 115
  • [4] Feasibility study on qualitative and quantitative analysis in tea by near infrared spectroscopy with multivariate calibration
    Chen, Quansheng
    Zhao, Jiewen
    Zhang, Haidong
    Wang, Xinyu
    [J]. ANALYTICA CHIMICA ACTA, 2006, 572 (01) : 77 - 84
  • [5] Conner AH, 1999, CONCISE POLYM MAT EN
  • [6] Conzen J., 2006, Multivariate Calibration: A practical guide for developing methods in the quantitative analytical chemistry
  • [7] HAM FM, 1994, PROCEEDINGS OF THE 16TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY - ENGINEERING ADVANCES: NEW OPPORTUNITIES FOR BIOMEDICAL ENGINEERS, PTS 1&2, P818, DOI 10.1109/IEMBS.1994.415160
  • [8] Determination of formaldehyde/urea molar ratio in amino resins by near-infrared spectroscopy
    Henriques, Ana
    Cruz, Paulo
    Martins, Jorge
    Ferra, Joao M.
    Magalhaes, Fernao D.
    Carvalho, Luisa H.
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 124 (03) : 2441 - 2448
  • [9] GRAPHICAL ABSORBANCE-RATIO METHOD FOR RAPID 2-COMPONENT SPECTROPHOTOMETRIC ANALYSIS
    HIRT, RC
    KING, FT
    SCHMITT, RG
    [J]. ANALYTICAL CHEMISTRY, 1954, 26 (08) : 1270 - 1273
  • [10] Hse CY, 2008, FOREST PROD J, V58, P56