Monte Carlo validation of a multireader method for receiver operating characteristic discrete rating data: Split plot experimental design

被引:8
作者
Dorfman, DD [1 ]
Berbaum, KS [1 ]
Lenth, RV [1 ]
Chen, YF [1 ]
机构
[1] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
来源
MEDICAL IMAGING 1999: IMAGE PERCEPTION AND PERFORMANCE | 1999年 / 3663卷
关键词
receiver operating characteristic curve (ROC); diagnostic radiology; decision theory; analysis of variance;
D O I
10.1117/12.349629
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The major purpose of this paper was to evaluate the Dorfman/Berbaum/Metz(1) (DBM) method for analyzing multireader receiver operating characteristic (ROC) discrete rating data on reader split-plot and case split-plot designs. It is not always appropriate or practical for readers to interpret imaging studies of the same patients in all modalities. In split plot designs, either a different sample of readers is assigned to each modality or a different sample of cases is assigned to each modality. For each type of split-plot design, a series of null-case Monte Carlo simulations were conducted. The results suggest that the DBM method provides trustworthy alpha levels with discrete ra-tings when ROC area is not too large, and case and reader sample sizes are not too small. In other situations, the test tends to be somewhat conservative. Our Monte Carlo simulations show that the DBM multireader method can be validly extended to the reader-split and case-split plot designs.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 15 条
[1]  
*AM COLL RAD, 1993, BREAST IM REP DAT SY
[2]  
[Anonymous], 1983, Statistical methods
[3]   DEGENERACY AND DISCRETE RECEIVER OPERATING CHARACTERISTIC RATING DATA [J].
DORFMAN, DD ;
BERBAUM, KS .
ACADEMIC RADIOLOGY, 1995, 2 (10) :907-915
[4]   Proper receiver operating characteristic analysis: The bigamma model [J].
Dorfman, DD ;
Berbaum, KS ;
Metz, CE ;
Lenth, RV ;
Hanley, JA ;
AbuDagga, H .
ACADEMIC RADIOLOGY, 1997, 4 (02) :138-149
[5]   Monte Carlo validation of a multireader method for receiver operating characteristic discrete rating data: Factorial experimental design [J].
Dorfman, DD ;
Berbaum, KS ;
Lenth, RV ;
Chen, YF ;
Donaghy, BA .
ACADEMIC RADIOLOGY, 1998, 5 (09) :591-602
[6]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[7]   ON THE VALIDITY OF THE CONTINUOUS AND DISCRETE CONFIDENCE RATING-SCALES IN RECEIVER OPERATING CHARACTERISTIC STUDIES [J].
KING, JL ;
BRITTON, CA ;
GUR, D ;
ROCKETTE, HE ;
DAVIS, PL .
INVESTIGATIVE RADIOLOGY, 1993, 28 (10) :962-963
[8]  
Metz CE, 1990, 1990 JOINT STAT M AM
[9]   Simple steps for improving multiple-reader studies in radiology [J].
Obuchowski, NA ;
Zepp, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) :517-521
[10]   The ''proper'' binormal model: Parametric receiver operating characteristic curve estimation with degenerate data [J].
Pan, XC ;
Metz, CE .
ACADEMIC RADIOLOGY, 1997, 4 (05) :380-389