Multislice CT angiography of the iliac arteries in the presence of various stents - In vitro evaluation of artifacts and lumen visibility

被引:37
作者
Maintz, D [1 ]
Fischbach, R [1 ]
Juergens, KU [1 ]
Allkemper, T [1 ]
Wessling, J [1 ]
Heindel, W [1 ]
机构
[1] Univ Munster, Dept Clin Radiol, Munster, Germany
关键词
stents and prostheses; multislice computed tomography; CT angiography; artifacts;
D O I
10.1097/00004424-200112000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS. Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were implanted in plastic tubes with an 8-mm inner diameter filled with iodinated contrast medium diluted to 200 HU. To evaluate the influence of scan parameters on artifacts, the Palmaz stent (as one example) was scanned with a four-slice scanner (Siemens VolumeZoom) with different detector collimations and pitches. All other stents were examined with a collimation of 4 x I min and a table feed of 4 mm/rotation. Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. RESULTS. Higher pitch values caused more pronounced artifacts. Image quality and delineation of the stent struts improved with thinner detector collimation. The size of the stent-related artifacts and the visibility of the stent lumen depended on the underlying stent material and design. Pronounced artifacts, resulting in an insufficient delineation of the stent lumen, were caused by the Strecker tantalum stent and the Zenith stent. Moderate artifacts were caused by the Wallgraft, Passager, Palmaz P 395 and P 424, Bridge, Perflex, and ZA stents. Some artificial lumen narrowing but good lumen delineation was seen with the Strecker nitinol, Symphony, Memotherm, SMART, Corinthian, and Wallstent stents. CONCLUSIONS. Scanning parameters, stent material, and stent design influence lumen assessability and image quality in MSCTA. Detailed lumen assessment is impossible in the Strecker tantalum and Zenith stents and limited in the Wallgraft, Passager, Palmaz P 395 and PS 424, Bridge, Perflex, and ZA-stent stent-grafts but feasible in all other examined products.
引用
收藏
页码:699 / 704
页数:6
相关论文
共 12 条
  • [1] Metallic artifacts of coronary and iliac arteries stents in mr angiography and contrast-enhanced CT
    Amano, Y
    Ishihara, M
    Hayashi, H
    Gemma, K
    Kawamata, H
    Amano, M
    Kumazaki, T
    [J]. CLINICAL IMAGING, 1999, 23 (02) : 85 - 89
  • [2] Subsecond multi-slice computed tomography: basics and applications
    Klingenbeck-Regn, K
    Schaller, S
    Flohr, T
    Ohnesorge, B
    Kopp, AF
    Baum, U
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) : 110 - 124
  • [3] Kramer SC, 1998, ANGIOLOGY, V49, P599
  • [4] Stent appearance at contrast-enhanced MR Angiography:: In vitro examination with 14 stents
    Lenhart, M
    Völk, M
    Manke, C
    Nitz, WR
    Strotzer, M
    Feuerbach, S
    Link, J
    [J]. RADIOLOGY, 2000, 217 (01) : 173 - 178
  • [5] Iliofemoral arterial occlusive disease: Contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement
    Link, J
    Steffens, JC
    Brossman, J
    Graessner, J
    Hackethal, S
    Heller, M
    [J]. RADIOLOGY, 1999, 212 (02) : 371 - 377
  • [6] In vitro evaluation of intravascular stent artifacts in three-dimensional MR angiography
    Maintz, D
    Kugel, H
    Schellhammer, F
    Landwehr, P
    [J]. INVESTIGATIVE RADIOLOGY, 2001, 36 (04) : 218 - 224
  • [7] Aorta and iliac arteries: Single versus multiple detector-row helical CT angiography
    Rubin, GD
    Shiau, MC
    Leung, AN
    Kee, ST
    Logan, LJ
    Sofilos, MC
    [J]. RADIOLOGY, 2000, 215 (03) : 670 - 676
  • [8] Pelvic and lower extremity arterial imaging: Diagnostic performance of three-dimensional contrast-enhanced MR angiography
    Ruehm, SG
    Hany, TF
    Pfammatter, T
    Schneider, E
    Ladd, M
    Debatin, JF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) : 1127 - 1135
  • [9] SCHULTE C, 2001, EUR RADIOL, V11, P179
  • [10] Aortoiliac and lower extremity arteries: Comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography
    Sueyoshi, E
    Sakamoto, I
    Matsuoka, Y
    Ogawa, Y
    Hayashi, H
    Hashmi, R
    Hayashi, K
    [J]. RADIOLOGY, 1999, 210 (03) : 683 - 688