Improved haemodynamics and restoration of spontaneous circulation with constant aortic occlusion during experimental cardiopulmonary resuscitation

被引:49
作者
Gedeborg, R [1 ]
Rubertsson, S [1 ]
Wiklund, L [1 ]
机构
[1] Univ Uppsala Hosp, Dept Surg Sci Anaesthesiol & Intens Care, S-75185 Uppsala, Sweden
关键词
cardiopulmonary resuscitation; aortic occlusion; cardiac output; myocardial blood flow; return of spontaneous circulation;
D O I
10.1016/S0300-9572(99)00021-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Continuous balloon occlusion of the descending aorta is an experimental method that may improve blood flow to the myocardium and the brain during cardiopulmonary resuscitation (CPR). The aim of the present investigation was to evaluate the effects of this intervention on haemodynamics and the frequency of restoration of spontaneous circulation. Ventricular fibrillation was induced in 39 anaesthetised piglets, followed by an 8-min non-intervention interval. In a haemodynamic study (n = 10), closed chest CPR was performed for 7 min before the intra-aortic balloon was inflated. This intervention increased mean arterial blood pressure by 20%. reduced cardiac output by 33%, increased coronary artery blood flow by 86%, and increased common carotid artery blood flow by 62%. All these changes were statistically significant. Administration of epinephrine further increased mean arterial blood pressure and coronary artery blood flow, while cardiac output and common carotid artery blood flow decreased. In a study of short-term survival, nine out of 13 animals (69%) in the balloon group and in three out of 13 animals (23%) in the control group had spontaneous circulation restored. The difference between these two proportions was 0.46, which was statistically significant with a 95% confidence interval from 0.12 to 0.80. In conclusion, balloon occlusion of the descending aorta increased coronary and common carotid artery blood dow and the frequency of restoration of spontaneous circulation. II was also noted that epinephrine appears to augment the redistribution of blood flow caused by the aortic occlusion. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:171 / 180
页数:10
相关论文
共 27 条
[1]   A randomized, blinded trial of high-dose epinephrine versus standard-dose epinephrine in a swine model of pediatric asphyxial cardiac arrest [J].
Berg, RA ;
Otta, CW ;
Kern, KB ;
Hilwig, RW ;
Sanders, AB ;
Henry, CP ;
Ewy, GA .
CRITICAL CARE MEDICINE, 1996, 24 (10) :1695-1700
[2]   HIGH-DOSE EPINEPHRINE RESULTS IN GREATER EARLY MORTALITY AFTER RESUSCITATION FROM PROLONGED CARDIAC-ARREST IN PIGS - A PROSPECTIVE, RANDOMIZED STUDY [J].
BERG, RA ;
OTTO, CW ;
KERN, KB ;
SANDERS, AB ;
HILWIG, RW ;
HANSEN, KK ;
EWY, GA .
CRITICAL CARE MEDICINE, 1994, 22 (02) :282-290
[3]   EPINEPHRINE DOSAGE EFFECTS ON CEREBRAL AND MYOCARDIAL BLOOD-FLOW IN AN INFANT SWINE MODEL OF CARDIOPULMONARY-RESUSCITATION [J].
BERKOWITZ, ID ;
GERVAIS, H ;
SCHLEIEN, CL ;
KOEHLER, RC ;
DEAN, JM ;
TRAYSTMAN, RJ .
ANESTHESIOLOGY, 1991, 75 (06) :1041-1050
[4]   A COMPARISON OF STANDARD-DOSE AND HIGH-DOSE EPINEPHRINE IN CARDIAC-ARREST OUTSIDE THE HOSPITAL [J].
BROWN, CG ;
MARTIN, DR ;
PEPE, PE ;
STUEVEN, H ;
CUMMINS, RO ;
GONZALEZ, E ;
JASTREMSKI, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (15) :1051-1055
[5]   COMPARATIVE EFFECT OF GRADED DOSES OF EPINEPHRINE ON REGIONAL BRAIN BLOOD-FLOW DURING CPR IN A SWINE MODEL [J].
BROWN, CG ;
WERMAN, HA ;
DAVIS, EA ;
HAMLIN, R ;
HOBSON, J ;
ASHTON, JA .
ANNALS OF EMERGENCY MEDICINE, 1986, 15 (10) :1138-1144
[6]   A RANDOMIZED CLINICAL-TRIAL OF HIGH-DOSE EPINEPHRINE AND NOREPINEPHRINE VS STANDARD-DOSE EPINEPHRINE IN PREHOSPITAL CARDIAC-ARREST [J].
CALLAHAM, M ;
MADSEN, CD ;
BARTON, CW ;
SAUNDERS, CE ;
POINTER, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 268 (19) :2667-2672
[7]  
CHASE PB, 1990, ANN EMERG MED, V19, P466
[8]  
COLETTI RH, 1983, T AM SOC ART INT ORG, V29, P93
[9]   Haemodynamic effects of descending aortic occlusion during cardiopulmonary resuscitation [J].
Deakin, CD ;
Barron, DJ .
RESUSCITATION, 1996, 33 (01) :49-52
[10]   HEMODYNAMIC-EFFECTS OF THE INTRA-AORTIC BALLOON PUMP DURING EXPERIMENTAL CARDIAC-ARREST [J].
EMERMAN, CL ;
PINCHAK, AC ;
HAGEN, JF ;
HANCOCK, D .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1989, 7 (04) :378-383