Continuous hemodynamic monitoring during laparoscopic gastric bypass in superobese patients by pressure recording analytical method

被引:19
作者
Balderi, Tania [2 ]
Forfori, Francesco [1 ,2 ]
Marra, Valeria [2 ]
Di Salvo, Claudio [2 ]
Dorigo, Massimo [2 ]
Anselmino, Marco [3 ]
Romano, Salvatore Mario [4 ]
Giunta, Francesco [2 ]
机构
[1] Azienda Osped Univ Pisana, Anestesia & Rianimaz Univ 4, Pisa, Italy
[2] Univ Pisa, Dept Surg, Div Anesthesiol & Intens Care, Pisa, Italy
[3] Azienda Osped Pisana, Bariatr Surg Unit, Pisa, Italy
[4] Univ Florence, Unit Internal Med & Cardiol, Dept Crit Care Med, Florence, Italy
关键词
morbid obesity; laparoscopic gastric bypass; pneumoperitoneum; pulse contour analysis; pressure recording analytical method;
D O I
10.1007/s11695-007-9379-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Morbid obesity, compromising cardiovascular and respiratory function, may increase the risk of anesthesia and was initially considered a contraindication to laparoscopy. The aim of this study was to investigate hemodynamic effects induced by pneumoperitoneum in superobese patients, assessed by arterial pulse contour method. Methods We prospectively studied 10 obese patients (BMI 53 +/- 9 kg/m(2)), scheduled for laparoscopic gastric bypass. After anesthesia induction, patients were intubated and mechanically ventilated. A radial artery was cannulated to obtain hemodynamic data implemented by means of a new pulse contour analysis method-the pressure recording analytical method (PRAM). Data were recorded after anesthesia induction (Tbas), at peritoneal insufflation (T0), at 1, 3, 5, 10, 30, and 60 min after pneumoperitoneurn induction (T1, T3, T5, T10, T15, T30, T60), at abdominal desufflation (Tdef) and 5 min after desufflation (T5def). Results MAP increased after pneumoperitoneum, returning to its baseline after deflation (79 +/- 7 Tbas, 81 +/- 6 mmHg T5def). HR remained unchanged. Systemic vascular resistance index (SVRI) increased after pneumoperitoneum induction and progressively returned to baseline (3,903 +/- 330 Tbas, 4,596 +/- 148 T1, and 3,786 +/- 202 dyn s m(2) cm(-5) T5def). Stroke volume index (SVI) and cardiac index (CI) increased after pneumoperitoneurn and remained elevated. Stroke volume variation (SVV) decreased after insufflation remaining lower than the basal value (28 +/- 4% Tbas, 15 +/- 5% T5des). Cardiac Cycle Efficiency (CCE) transient decreased after insufflation and subsequently increased (0.029 +/- 0.146 Tbas, 0.008 +/- 0.178 T5def). Aortic dP/dt max increased after insufflation, returning to baseline only after desufflation (0.68 +/- 0.07 Tbas, 0.94 +/- 0.08 T30 and 0.86 +/- 0.06 mmHg s(-1) T5def). Conclusion As assessed by PRAM, this study showed no deterioration in hemodynamic indices or ventricular performance during laparoscopic gastric bypass.
引用
收藏
页码:1007 / 1014
页数:8
相关论文
共 39 条
[1]   Cardiac function during intraperitoneal CO2 insufflation for aortic surgery:: A transesophageal echocardiographic study [J].
Alfonsi, P ;
Vieillard-Baron, T ;
Coggia, M ;
Guignard, B ;
Goeau-Brissonniere, O ;
Jardin, F ;
Chauvin, M .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1304-1310
[2]   Hemodynamic changes during laparoscopic gastric bypass procedures [J].
Artuso, D ;
Wayne, M ;
Cassaro, S ;
Cerabona, V ;
Teixeira, J ;
Grossi, R .
ARCHIVES OF SURGERY, 2005, 140 (03) :289-292
[3]  
Bakri M, 2007, CURR OPIN ANAESTH, V5, P172
[4]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[5]   TRANSESOPHAGEAL ECHOCARDIOGRAPHIC ASSESSMENT OF HEMODYNAMIC FUNCTION DURING LAPAROSCOPIC CHOLECYSTECTOMY [J].
CUNNINGHAM, AJ ;
TURNER, J ;
ROSENBAUM, S ;
RAFFERTY, T .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (06) :621-625
[6]   Hemodynamic changes during laparoscopic gastroplasty in morbidly obese patients [J].
Dumont, L ;
Mattys, M ;
Mardirosoff, C ;
Picard, V ;
Alle, JL ;
Massaut, J .
OBESITY SURGERY, 1997, 7 (04) :326-331
[7]  
Fried M, 2001, OBES SURG, V11, P293
[8]   Effects of posture and pneumoperitoneum during anaesthesia on the indices of left ventricular filling [J].
Gannedahl, P ;
Odeberg, S ;
Brodin, LA ;
Sollevi, A .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (02) :160-166
[9]   Cardiac output monitoring by pressure recording analytical method in cardiac surgery [J].
Giomarelli, P ;
Biagioli, B ;
Scolletta, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) :515-520
[10]   The effect of laparoscopic cholecystectomy on cardiovascular function and pulmonary gas exchange [J].
Girardis, M ;
DaBroi, U ;
Antonutto, G ;
Pasetto, A .
ANESTHESIA AND ANALGESIA, 1996, 83 (01) :134-140