A fluorescent in situ hybridization method in flow cytometry to detect HIV-1 specific RNA

被引:15
作者
Borzi, RM
Piacentini, A
Monaco, MCG
Lisignoli, G
Degrassi, A
Cattini, L
Santi, S
Facchini, A
机构
[1] IST RIC CODIVILLA PUTTI,IOR,LAB IMMUNOL & GENET,I-40136 BOLOGNA,ITALY
[2] IST RIC CODIVILLA PUTTI,IOR,LAB BIOL CELLULARE & MICROSCOPIA ELETTRON,I-40136 BOLOGNA,ITALY
[3] UNIV BOLOGNA,IST CLIN MED & GASTROENTEROL,I-40126 BOLOGNA,ITALY
[4] UNIV UDINE,DIPARTIMENTO PATOL & MED SPERIMENTALE & CLIN,I-33100 UDINE,ITALY
[5] UNIV UDINE,CONSORZIO RIC BIOMED,I-33100 UDINE,ITALY
[6] NINCDS,LAB MOLEC MED & NEUROSCI,NIH,BETHESDA,MD 20892
关键词
fluorescent in situ hybridization; HIV-RNA; flow cytometry;
D O I
10.1016/0022-1759(96)00070-1
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
In HIV+ patients, the presence of HIV-RNA in plasma and circulating cells has been reported to be a marker of progression but the percentage of transcriptionally active infected cells remains unclear. We have developed a reliable fluorescent in situ hybridization method for the detection of HIV specific RNA by flow cytometry. The procedure was applied to a panel of chronically infected cell lines and to an acutely infected cell line mimicking normal peripheral blood lymphocytes in susceptibility to HIV-1. The cells were fixed in suspension and hybridized by means of an HIV-1 genomic probe labeled with digoxigenin-11-dUTP. An FTTC-labeled anti-digoxigenin antiserum was then applied and the resulting fluorescence signals were analyzed both by flow cytometry and confocal microscopy. Different procedures for double staining HIV-RNA together with virus induced proteins or surface markers were also developed. Flow cytometric detection of in situ hybridization offers the possibility of analyzing thousands of cells in a few seconds and of collecting multiparametric information at the single cell level, thus providing a potential tool for detecting the rare HIV-RNA expressing cells in peripheral blood samples.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 36 条
[1]
PRODUCTION OF ACQUIRED IMMUNODEFICIENCY SYNDROME-ASSOCIATED RETROVIRUS IN HUMAN AND NONHUMAN CELLS TRANSFECTED WITH AN INFECTIOUS MOLECULAR CLONE [J].
ADACHI, A ;
GENDELMAN, HE ;
KOENIG, S ;
FOLKS, T ;
WILLEY, R ;
RABSON, A ;
MARTIN, MA .
JOURNAL OF VIROLOGY, 1986, 59 (02) :284-291
[2]
RECOVERY OF INFECTIOUS HUMAN-IMMUNODEFICIENCY-VIRUS FROM CELLS TREATED WITH 1-PERCENT PARAFORMALDEHYDE [J].
ALOISIO, CH ;
NICHOLSON, JKA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 128 (02) :281-285
[3]
DETECTION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 PROVIRUS IN MONONUCLEAR-CELLS BY INSITU POLYMERASE CHAIN-REACTION [J].
BAGASRA, O ;
HAUPTMAN, SP ;
LISCHNER, HW ;
SACHS, M ;
POMERANTZ, RJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (21) :1385-1391
[4]
FLOW CYTOMETRIC DETECTION OF RIBOSOMAL-RNA IN SUSPENDED CELLS BY FLUORESCENT INSITU HYBRIDIZATION [J].
BAUMAN, JGJ ;
BENTVELZEN, P .
CYTOMETRY, 1988, 9 (06) :517-524
[5]
FLUORESCENT INSITU HYBRIDIZATION TO DETECT CELLULAR RNA BY FLOW-CYTOMETRY AND CONFOCAL MICROSCOPY [J].
BAUMAN, JGJ ;
BAYER, JA ;
VANDEKKEN, H .
JOURNAL OF MICROSCOPY-OXFORD, 1990, 157 :73-81
[6]
FLOW CYTOMETRIC DETECTION OF BETA-GLOBIN MESSENGER-RNA IN MURINE HEMATOPOIETIC TISSUES USING FLUORESCENT INSITU HYBRIDIZATION [J].
BAYER, JA ;
BAUMAN, JGJ .
CYTOMETRY, 1990, 11 (01) :132-143
[7]
FLOW CYTOMETRIC ESTIMATION OF POLY(A)+ RNA BY FLUORESCENT INSITU HYBRIDIZATION [J].
BELLOC, F ;
LACOMBE, F ;
DUMAIN, P ;
MERGNY, JL ;
LOPEZ, F ;
BERNARD, P ;
REIFFERS, J ;
BOISSEAU, MR .
CYTOMETRY, 1993, 14 (03) :339-343
[8]
BURKE AP, 1993, AM J PATHOL, V142, P1701
[9]
EFFECTS OF CELLULAR FIXATIVES ON HUMAN-IMMUNODEFICIENCY-VIRUS PRODUCTION [J].
CORY, JM ;
RAPP, F ;
OHLSSONWILHELM, BM .
CYTOMETRY, 1990, 11 (05) :647-651
[10]
DETECTION OF CIRCULATING P24 ANTIGEN-POSITIVE CD4+ CELLS DURING HIV-INFECTION BY FLOW-CYTOMETRY [J].
COSTIGLIOLA, P ;
TUMIETTO, F ;
RICCHI, E ;
CHIODO, F .
AIDS, 1992, 6 (10) :1121-1125