Flexible (Polyactive(R)) versus rigid (hydroxyapatite) dental implants

被引:12
作者
Meijer, GJ
Heethaar, J
Cune, MS
DePutter, C
VanBlitterswijk, CA
机构
[1] UNIV UTRECHT, FAC MED, DEPT MED PHYS, NL-3507 TA UTRECHT, NETHERLANDS
[2] LEIDEN UNIV, FAC MED, BIOMAT RES GRP, LEIDEN, NETHERLANDS
[3] TECH UNIV TWENTE, TWENTE, NETHERLANDS
关键词
dental implants - flexible; hydroxyapatite;
D O I
10.1016/S0901-5027(05)80836-7
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
In a beagle dog study, the peri-implant bone changes around flexible (Polyactive(R)) and rigid hydroxyapatite (HA) implants were investigated radiographically by quantitative digital subtraction analysis and by assessment of marginal bone height, with the aid of a computerized method. A loss of approximately 1 mm of marginal bone height was observed for both the dense Polyactive and the HA implants, after 6 months of loading. This value appeared to be stable from 12 weeks of loading onward. Along the total length of the implant during the first 6 weeks of loading, both the flexible (dense Polyactive) and the rigid (HA) implants showed a decrease in density. However, after this 6-week period, the bone density around the implants increased, and after 18 weeks the original bone density was reached. The flexible Polyactive implants provoked less decrease in density than the rigid HA implants, although not to a statistically significant level. This finding sustains the hypothesis that flexible implant materials may transfer stresses to the surrounding bone more favorably.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
[1]
MARGINAL TISSUE-REACTIONS AT OSSEOINTEGRATED TITANIUM FIXTURES .1. A 3-YEAR LONGITUDINAL PROSPECTIVE-STUDY [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI ;
LINDHE, J ;
ERIKSSON, B ;
SBORDONE, L .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1986, 15 (01) :39-52
[2]
A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[3]
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[4]
TISSUE BIOMATERIAL INTERFACE CHARACTERISTICS OF 4 ELASTOMERS - A TRANSMISSION ELECTRON MICROSCOPICAL STUDY [J].
BAKKER, D ;
VANBLITTERSWIJK, CA ;
HESSELING, SC ;
DAEMS, WT ;
GROTE, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (03) :277-293
[5]
BIOCOMPATIBILITY OF A POLYETHER URETHANE, POLYPROPYLENE OXIDE, AND A POLYETHER POLYESTER COPOLYMER - A QUALITATIVE AND QUANTITATIVE STUDY OF 3 ALLOPLASTIC TYMPANIC MEMBRANE MATERIALS IN THE RAT MIDDLE-EAR [J].
BAKKER, D ;
VANBLITTERSWIJK, CA ;
HESSELING, SC ;
KOERTEN, HK ;
KUIJPERS, W ;
GROTE, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (04) :489-515
[6]
Bakker D., 1992, BONE BONDING BIOMATE, P13
[7]
BAKKER D, 1989, POLYM MED SURGERY, V6, P11
[8]
3-DIMENSIONAL STRESS-DISTRIBUTION AROUND A DENTAL IMPLANT AT DIFFERENT STAGES OF INTERFACE DEVELOPMENT [J].
BORCHERS, L ;
REICHART, P .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (02) :155-159
[9]
DIGITAL IMAGING IN PERIODONTAL RADIOGRAPHY - A REVIEW [J].
BRAGGER, U .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (09) :551-557
[10]
Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants [J].
Buser, D. ;
Weber, H-P ;
Lang, N. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) :33-40