Influence of the antagonist material on the wear of different composites using two different wear simulation methods

被引:48
作者
Heintze, SD
Zellweger, G
Cavalleri, A
Ferracane, J
机构
[1] Ivoclar Vivadent, In VitroRes, Res & Dev, FL-9494 Schaan, Liechtenstein
[2] Oregon Hlth Sci Univ, Dept Restorat Dent, Div Biomat & Biomech, Portland, OR 97201 USA
关键词
wear; composite; ceramic; stylus;
D O I
10.1016/j.dental.2005.04.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The aim of the study was to evaluate two ceramic materials as possible substitutes for enamel using two wear simulation methods, and to compare both methods with regard to the wear results for different materials. Methods. Flat specimens (OHSU n=6, Ivoclar n=8) of one compomer and three composite materials (Dyract AP, Tetric Ceram, Z250, experimental composite) were fabricated and subjected to wear using two different wear testing methods and two pressable ceramic materials as stylus (Empress, experimental ceramic). For the OHS method, enamel styli of the same dimensions as the ceramic stylus were fabricated additionally. Both wear testing methods differ with regard to loading force, lateral movement of stylus, stylus dimension, number of cycles, thermo-cycling and abrasive medium. In the OHSU method, the wear facets (mean vertical loss) were measured using a contact profilometer, white in the Ivoclar method (maximal. vertical loss) a laser scanner was used for this purpose. Additionally, the vertical toss of the ceramic stylus was quantified for the Ivoclar method. The results obtained from each method were compared by ANOVA and Tukey's test (p < 0.05). To compare both wear methods, the log-transformed data were used to establish relative ranks between material/stylus combinations and assessed by applying the Pearson correlation coefficient. Results. The experimental ceramic material generated significantly less wear in Tetric Ceram and Z250 specimens compared to the Empress stylus in the Ivoclar method, whereas with the OHSU method, no difference between the two ceramic antagonists was found with regard to abrasion or attrition. The wear generated by the enamel stylus was not statistically different from that generated by the other two ceramic materials in the OHSU method. With the Ivoclar method, wear of the ceramic stylus was only statistically different when in contact with Tetric Ceram. There was a close correlation between the attrition wear of the OHSU and the wear of the Ivoclar method (Pearson coefficient 0.83, p=0.01). Significance: Pressable ceramic materials can be used as a substitute for enamel in wear testing machines. However, material ranking may be affected by the type of ceramic material chosen. The attrition wear of the OHSU method was comparable with the wear generated with the Ivoclar method. (c) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:166 / 175
页数:10
相关论文
共 25 条
[1]  
[Anonymous], DEGRADATION DENT POL
[2]  
Condon JR, 1997, J BIOMED MATER RES, V38, P303, DOI 10.1002/(SICI)1097-4636(199724)38:4<303::AID-JBM2>3.0.CO
[3]  
2-S
[4]   Evaluation of composite wear with a new multi-mode oral wear simulator [J].
Condon, JR ;
Ferracane, JL .
DENTAL MATERIALS, 1996, 12 (04) :218-226
[5]   OCCLUSAL FORCES DURING CHEWING AND SWALLOWING AS MEASURED BY SOUND-TRANSMISSION [J].
GIBBS, CH ;
MAHAN, PE ;
LUNDEEN, HC ;
BREHNAN, K ;
WALSH, EK ;
HOLBROOK, WB .
JOURNAL OF PROSTHETIC DENTISTRY, 1981, 46 (04) :443-449
[6]   CHEWING MOVEMENTS IN RELATION TO BORDER MOVEMENTS AT THE 1ST MOLAR [J].
GIBBS, CH ;
LUNDEEN, HC ;
MAHAN, PE ;
FUJIMOTO, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1981, 46 (03) :308-322
[7]   Wear of ten dental restorative materials in five wear simulators - Results of a round robin test [J].
Heintze, SD ;
Zappini, G ;
Rousson, V .
DENTAL MATERIALS, 2005, 21 (04) :304-317
[8]   The influence of antagonist standardization on wear [J].
Krejci, I ;
Albert, P ;
Lutz, F .
JOURNAL OF DENTAL RESEARCH, 1999, 78 (02) :713-719
[9]  
Krejci I, 1990, Schweiz Monatsschr Zahnmed, V100, P953
[10]   EFFECT OF CONTACT AREA SIZE ON ENAMEL AND COMPOSITE WEAR [J].
KREJCI, I ;
LUTZ, F ;
ZEDLER, C .
JOURNAL OF DENTAL RESEARCH, 1992, 71 (07) :1413-1416