Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy

被引:144
作者
Bernstein, MA [1 ]
Fain, SB [1 ]
Riederer, SJ [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
关键词
zero-filling; windowing; spatial resolution; angular dependence; filtering;
D O I
10.1002/jmri.1183
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Standard, MR spin-warp sampling strategies acquire data on a rectangular k-space grid. That method samples data from the "corners" of k-space, i.e., data that lie in a region of k-space outside of an ellipse just inscribed in the rectangular boundary. Illustrative calculations demonstrate that the data in the corners of k-space contribute to the useful resolution only if an interpolation method such as a zero-filled reconstruction is used. The consequences of this finding on data acquisition and data windowing strategies are discussed. A further implication of this result is that the spatial resolution of images reconstructed with zero-filling {but without radial windowing) is expected to display angular dependence, even when the phase- and frequency-encoded resolutions are identical. This hypothesis is experimentally verified with a slit geometry phantom. It is also observed that images reconstructed without zero-filling do not display the angular dependence of spatial resolution predicted solely by the maximal k-space extent of the raw data. The implications of these results for 3D contrast-enhanced angiographic acquisitions with elliptical centric view ordering are explored with simulations. J. Magn. Reson. Imaging 2001;14:270-280. (C) 2001 Whey-Liss, Inc.
引用
收藏
页码:270 / 280
页数:11
相关论文
共 28 条
[1]   HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1. [J].
AHN, CB ;
KIM, JH ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :2-7
[2]  
AVINASH GB, Patent No. 5923789
[3]  
BERNSTEIN MA, 1995, P 3 SCI M SOC MAGN R, P734
[4]  
BERNSTEIN MA, 1999, P 7 ANN M ISMRM PHIL, P177
[5]  
COOPER TG, 1996, P 4 ANN M ISMRM NEW, P1609
[6]   REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL ;
CAO, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :733-741
[7]   MR DATA ACQUISITION AND RECONSTRUCTION USING EFFICIENT SAMPLING SCHEMES [J].
EHRHARDT, JC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (03) :305-309
[8]  
Fain SB, 1999, MAGNET RESON MED, V42, P1106, DOI 10.1002/(SICI)1522-2594(199912)42:6<1106::AID-MRM15>3.0.CO
[9]  
2-Q
[10]   VET imaging: Magnetic resonance imaging with variable encoding time [J].
Feinberg, DA .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :7-14