Evaluation of abdominal aortic aneurysm after endoluminal treatment: Comparison of color Doppler sonography with biphasic helical CT

被引:36
作者
Golzarian, J
Murgo, S
Dussaussois, L
Guyot, S
Said, KA
Wautrecht, JC
Struyven, J
机构
[1] Univ Brussels, Erasme Hosp, Dept Radiol, B-1070 Brussels, Belgium
[2] Univ Brussels, Erasme Hosp, Dept Vasc Pathol, B-1070 Brussels, Belgium
关键词
D O I
10.2214/ajr.178.3.1780623
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. The purpose of this study is to compare color Doppler sonography with biphasic helical CT in the evaluation of abdominal aortic aneurysms after endovascular repair. MATERIALS AND METHODS. Fifty-five patients prospectively underwent both color Doppler sonography and helical CT within 7 days after treatment by endovascular stent-graft. Aneurysmal thrombosis, the patency of the grafts, and the presence of a leak were evaluated in all patients. When a perigraft leak was observed, an attempt was made to identify its origin and outflow vessels. Helical CT was considered the gold standard technique. RESULTS. Helical CT revealed aneurysmal thrombosis in 33 patients and a perigraft leak in 22 patients. In five patients, helical C-F detected a small perigraft leak not shown by color Doppler sonography. In three patients with suboptimal examinations, color Doppler sonography revealed a suspected perigraft leak that was not confirmed by helical CT. In these eight patients, the perigraft leak was scaled or no longer observed during follow-up. Compared with enhanced helical CT, the sensitivity and specificity of color Doppler sonography for the diagnosis of a perigraft leak were 77% and 90%, respectively. In seven other patients, helical CT was superior to color Doppler sonography in detecting the origin of the perigraft leak and the outflow vessels. Two iliac artery dissections and one distal migration of the prosthesis were revealed only by helical CT. CONCLUSION. Although color Doppler sonography may detect substantial perigraft leaks, helical CT is superior for detecting the origin of the perigraft leak, the outflow vessels, and the detection of complications related to the procedure.
引用
收藏
页码:623 / 628
页数:6
相关论文
共 31 条
[1]
Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[2]
Early complications and endoleaks after endovascular abdominal aortic aneurysm repair: Report of a multicenter study - Discussion [J].
Parodi, JC ;
Buth, J .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (01) :145-146
[3]
Chuter T A, 1995, Cardiovasc Surg, V3, P121, DOI 10.1016/0967-2109(95)90884-8
[4]
Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: Complications and secondary radiologic intervention [J].
Dorffner, R ;
Thurnher, S ;
Polterauer, P ;
Kretschmer, G ;
Lammer, J .
RADIOLOGY, 1997, 204 (01) :79-86
[5]
Spiral CT angiography in the assessment of abdominal aortic aneurysms after stent grafting: Value of maximum intensity projections [J].
Dorffner, R ;
Thurnher, S ;
Youssefzadeh, S ;
Winkelbauer, F ;
Holzenbein, T ;
Polterauer, P ;
Lammer, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) :472-477
[6]
ELLIS M, 1990, CAUSE MANAGEMENT ANE, P117
[7]
Helical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition [J].
Golzarian, J ;
Dussaussois, L ;
Abada, HT ;
Gevenois, PA ;
Van Gansbeke, D ;
Ferreira, J ;
Struyven, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :329-331
[8]
Endovascular aortic stent-grafts: Transcatheter embolization of persistent perigraft leaks [J].
Golzarian, J ;
Struyven, J ;
Abada, HT ;
Wery, D ;
Dussaussois, L ;
Madani, A ;
Ferreira, J ;
Dereume, JP .
RADIOLOGY, 1997, 202 (03) :731-734
[9]
Harris P, 1999, J ENDOVASC SURG, V6, P11, DOI 10.1583/1074-6218(1999)006<0011:LASFEA>2.0.CO
[10]
2