A Report on the International Transglutaminase Autoantibody Workshop for Celiac Disease

被引:97
作者
Li, Marcella [1 ]
Yu, Liping [1 ]
Tiberti, Claudio [2 ]
Bonamico, Margherita [2 ]
Taki, Iman [1 ]
Miao, Dongmei [1 ]
Murray, Joseph A. [3 ]
Rewers, Marian J. [1 ]
Hoffenberg, Edward J. [1 ]
Agardh, Daniel [4 ]
Mueller, Patricia [5 ]
Stern, Martin [6 ]
Bonifacio, Ezio [7 ]
Liu, Edwin [1 ]
机构
[1] Univ Colorado Denver, Aurora, CO USA
[2] Univ Roma La Sapienza, Dept Clin Sci, Policlin Umberto I, Rome, Italy
[3] Mayo Clin, Div Gastroenterol & Hepatol, Rochester, MN USA
[4] Lund Univ, Malmo Univ Hosp, Dept Clin Sci, Unit Diabet & Celiac Dis, S-22100 Lund, Sweden
[5] Ctr Dis Control & Prevent, Mol Risk Assessment Lab, NSMBB, DLS,NCEH, Atlanta, GA USA
[6] Univ Childrens Hosp, Dept Pediat, Tubingen, Germany
[7] Diabet Res Inst, Munich, Germany
基金
美国国家卫生研究院;
关键词
TISSUE TRANSGLUTAMINASE; IDENTIFICATION; ASSAYS;
D O I
10.1038/ajg.2008.8
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: Measurement of transglutaminase autoantibodies (TGAA) is considered to be the most efficient single serologic test for celiac disease (CD) by the American Gastroenterological Association Institute. We hypothesized that a large international collaborative effort toward improving and standardizing TGAA measurement is both feasible and necessary. The primary aim of this workshop is to compare TGAA assays among various research and clinical laboratories and examine assay concordance and improve (and eventually standardize) the TGAA assay. METHODS: A total of 20 laboratories (5 commercial laboratories, 15 research and clinical laboratories) participated that included enzyme-linked immunosorbent assay (ELISA) and radiobinding assays. A total of 150 serum samples were distributed to each laboratory, with each laboratory receiving an equal aliquot that was coded and blinded, composed of 100 healthy control sera and 50 CD sera. RESULTS: Laboratory sensitivity ranged from 69% to 93% and specificity ranged from 96% to 100%. By receiver operator characteristic analysis, the area under the curve (C index) ranged from 0.9488 to 0.9904. When analyzing for linear correlation, r-squared was as high as 0.8882 but as low as 0.4244 for the celiac samples between different laboratories performing ELISA. CONCLUSIONS: This transglutaminase autoantibody workshop allows for larger-scale international participation for the purposes of improving and eventually standardizing the TGAA assay with subsequent workshops.
引用
收藏
页码:154 / 163
页数:10
相关论文
共 15 条
[1]  
[Anonymous], 2004, NIH Consens State Sci Statements, V21, P1
[2]   Diabetes antibody standardization program: First assay proficiency evaluation [J].
Bingley, PJ ;
Bonifacio, E ;
Mueller, PW .
DIABETES, 2003, 52 (05) :1128-1136
[3]  
Bonamico M, 2001, AM J GASTROENTEROL, V96, P1536
[4]   International workshop on lessons from animal models for human type 1 diabetes - Identification of insulin but not glutamic acid decarboxylase or IA-2 as specific autoantigens of humoral autoimmunity in nonobese diabetic mice [J].
Bonifacio, E ;
Atkinson, M ;
Eisenbarth, G ;
Serreze, D ;
Kay, TWH ;
Lee-Chan, E ;
Singh, B .
DIABETES, 2001, 50 (11) :2451-2458
[5]   Identification of tissue transglutaminase as the autoantigen of celiac disease [J].
Dieterich, W ;
Ehnis, T ;
Bauer, M ;
Donner, P ;
Volta, U ;
Riecken, EO ;
Schuppan, D .
NATURE MEDICINE, 1997, 3 (07) :797-801
[6]   Guideline for the diagnosis and treatment of celiac disease in children: Recommendations of the North American Society for Pediatric Gastroenterology, Hepatology and Nutrition [J].
Hill, ID ;
Dirks, MH ;
Liptak, GS ;
Colletti, RB ;
Fasano, A ;
Guandalini, S ;
Hoffenberg, EJ ;
Horvath, K ;
Murray, JA ;
Pivor, M ;
Seidman, EG .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2005, 40 (01) :1-19
[7]   AGA Institute Medical Position Statement on the Diagnosis and Management of Celiac Disease [J].
Kagnoff, Martin F. .
GASTROENTEROLOGY, 2006, 131 (06) :1977-1980
[8]   Need for quantitative assessment of transglutaminase autoantibodies for celiac disease in screening-identified children [J].
Liu, E ;
Li, M ;
Bao, F ;
Miao, DM ;
Rewers, MJ ;
Eisenbarth, GS ;
Hoffenberg, EJ .
JOURNAL OF PEDIATRICS, 2005, 146 (04) :494-499
[9]   Accepting clocks that tell time poorly: Fluid-phase versus standard ELISA autoantibody assays [J].
Liu, Edwin ;
Eisenbarth, George S. .
CLINICAL IMMUNOLOGY, 2007, 125 (02) :120-126
[10]   Comparative evaluation of serologic tests for celiac disease: A European initiative toward standardization [J].
Stern, M .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2000, 31 (05) :513-519