Cardiac output and circulating blood volume analysis by pulse dye-densitometry

被引:153
作者
Iijima, T
Aoyagi, T
Iwao, Y
Masuda, J
Fuse, M
Kobayashi, N
Sankawa, H
机构
[1] Department of Anesthesiology, School of Medicine, Kyorin University
[2] Department of Anesthesiology, Kyorin University, School of Medicine, Mitaka City, Tokyo 181
关键词
cardiac output; circulating blood volume; dye dilution method; indocyanine green; thermodilution methods; pulse dye-densitometry; pulse oximetry;
D O I
10.1023/A:1007339924083
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. Pulse dye-densitometry (PDD) is a newly developed method for monitoring the indocyanine green (ICG) concentration in an artery with which cardiac output (CO) and circulating blood volume (CBV) can be determined. We evaluated its accuracy for clinical use. Methods. In 7 patients under general anesthesia, ICG-sensitive optical probes (805 and 890nm) were attached to a finger. Following injection of ICG, the arterial concentration of dye was recorded optically by the non-invasive test instrument and sampled arterial blood ICG concentration was also measured photometrically for comparison. In order to validate the PDD analysis, CO was also measured by both the dye dilution cuvette method and by thermodilution in 8 patients scheduled for coronary artery bypass grafting. In 30 other patients, CBV assessed by PDD was compared with its value estimated from body size. Results. The blood dye concentration correlated well with the values obtained by PDD (r = 0.953, p < 0.01). Mean bias for the test PDD CO was +0.15 +/- 0.72 min l(-1) (not significant (n.s)) compared with the cuvette method while the mean bias of the thermodilution method vs the cuvette method was +0.79 +/- 0.84 min l(-1) (p < 0.0001.). The average value of CBV obtained by PDD was 3.81 +/- 1.39 L compared with that estimated value, 3.72 +/- 0.77 L (n.s). Conclusions. CO determined by PDD agrees well with cuvette densitometry, and somewhat less well with CO by thermodilution. The new method, by not requiring a pulmonary arterial catheter, is less invasive than either older method, and yields in addition a value of CBV.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 28 条
[1]  
Albert SN, 1971, BLOOD VOLUME EXTRACE
[2]  
Aoyagi T., 1992, Japanese Journal of Medical Electronics and Biological Engineering, V30, P1
[3]  
AOYAGI T, 1992, IEEE ANN M PARIS
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   DETERMINATION OF BLOOD VOLUME USING INDOCYANINE GREEN (CARDIO-GREENR) DYE [J].
BRADLEY, EC ;
BARR, JW .
LIFE SCIENCES PART 1 PHYSIOLOGY AND PHARMACOLOGY AND PART 2 BIOCHEMISTRY GENERAL AND MOLECULAR BIOLOGY, 1968, 7 (17P1) :1001-&
[6]  
CORDTS PR, 1992, SURG GYNECOL OBSTET, V175, P243
[7]  
de Vries J P, 1992, ASAIO J, V38, pM181, DOI 10.1097/00002480-199207000-00015
[8]   PREVENTION OF INTRAOPERATIVE ANESTHESIA ACCIDENTS AND RELATED SEVERE INJURY THROUGH SAFETY MONITORING [J].
EICHHORN, JH .
ANESTHESIOLOGY, 1989, 70 (04) :572-577
[9]  
EIDELMAN LA, 1994, CRIT CARE MED, V22, P543
[10]   LESS-INVASIVE CARDIAC-OUTPUT MONITORING BY EARPIECE DENSITOMETRY [J].
GRASBERGER, RC ;
YESTON, NS .
CRITICAL CARE MEDICINE, 1986, 14 (06) :577-579