Influence of bipolar esophageal electrode positioning on measurements of human crural diaphragm electromyogram

被引:65
作者
Beck, J
Sinderby, C
Lindstrom, L
Grassino, A
机构
[1] UNIV MONTREAL,HOP NOTRE DAME,MONTREAL,PQ H2L 4M1,CANADA
[2] SAHLGRENS UNIV HOSP,SPINAL INJURIES UNIT,S-41345 GOTHENBURG,SWEDEN
关键词
cross-correlation analysis; center frequency; root mean square; signal contamination;
D O I
10.1152/jappl.1996.81.3.1434
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We aimed to describe how the human diaphragm electromyogram (EMGdi) is filtered at different positions within the esophageal hiatus, i.e., in the close proximity of the diaphragm, when obtained with an array of bipolar electrode pairs mounted on an esophageal catheter. We defined the electrically active crural diaphragm musculature that covers the esophagus as the electrically active region of the diaphragm (EAR(di)) and its center as the EAR(di) center. EMGdi signals were obtained via a multiple-array esophageal catheter consisting of seven sequential electrode pairs with three different electrode configurations. Subjects (n = 5) performed voluntary contractions of the diaphragm at functional residual capacity. Visual inspection of the signals revealed reversal of signal polarity on either side of the EAR(di) center. Extreme correlation values (r values close to -1 at 0-ms time offset) were observed for the correlation of signals on either side of the EAR(di) center; moving peripherally from the EAR(di) center (caudally and cephalad), the RMS increased to a peak (range of 2.1-4.1 dB for the different electrode configurations) and then decreased for the most peripheral electrode pairs. From a position where the RMS values peaked, center frequency values increased at the EAR(di) center (range of 26-29 Hz for the different electrode configurations). Computer simulation yielded similar data to the experimental results. We conclude that electride positioning within the EAR(di) severely influences center frequency and RMS values and that the center of the EAR(di) can be identified cia cross-correlation analysis.
引用
收藏
页码:1434 / 1449
页数:16
相关论文
共 37 条
[1]   ELECTROMYOGRAPHY OF THE DIAPHRAGM IN MAN AND TRANSDIAPHRAGMATIC PRESSURE [J].
AGOSTONI, E ;
SANTAMBROGIO, G ;
CARRASCO, HD .
JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (06) :1093-1097
[2]   POWER SPECTRAL-ANALYSIS OF THE DIAPHRAGM ELECTROMYOGRAM [J].
ALDRICH, TK ;
ADAMS, JM ;
ARORA, NS ;
ROCHESTER, DF .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (06) :1579-1584
[3]  
ALLISON PR, 1951, SURG GYNECOL OBSTET, V92, P419
[4]   EFFECTS OF MUSCLE-TO-ELECTRODE DISTANCE ON THE HUMAN DIAPHRAGM ELECTROMYOGRAM [J].
BECK, J ;
SINDERBY, C ;
WEINBERG, J ;
GRASSINO, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (03) :975-985
[5]   EVALUATION OF HUMAN DIAPHRAGM FATIGUE [J].
BELLEMARE, F ;
GRASSINO, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (05) :1196-1206
[6]   FORCE RESERVE OF THE DIAPHRAGM IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
BELLEMARE, F ;
GRASSINO, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (01) :8-15
[7]  
BENDAT JS, 1971, RANDOM DATA ANAL MEA, P1
[8]  
BOTROS KG, 1990, ANAT ANZEIGER, V171, P193
[9]  
CAREY JM, 1955, SURG GYNECOL OBSTET, V100, P196
[10]   CLINICAL MANIFESTATIONS OF INSPIRATORY MUSCLE FATIGUE [J].
COHEN, CA ;
ZAGELBAUM, G ;
GROSS, D ;
ROUSSOS, C ;
MACKLEM, PT .
AMERICAN JOURNAL OF MEDICINE, 1982, 73 (03) :308-316