Physical activity monitoring based on accelerometry: validation and comparison with video observation

被引:212
作者
Aminian, K [1 ]
Robert, P
Buchser, EE
Rutschmann, B
Hayoz, D
Depairon, M
机构
[1] Swiss Fed Inst Technol, Dept Elect Engn, Metrol Lab, CH-1015 Lausanne, Switzerland
[2] Hop Morges Morges, Lausanne, Switzerland
[3] CHU Vaudois, CH-1011 Lausanne, Switzerland
关键词
physical activity; accelerometer; ambulatory system;
D O I
10.1007/BF02513304
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The objective of this feasibility study is to evaluate the use of the 'Physilog' device, an ambulatory physical-activity recorder based on acceleration measurement, for the monitoring of daily physical activities. Accelerations measured at the level of the chest and the thigh are recorded by Physilog over a period of 1 h in five normal subjects. A specially designed studio-like room allowing the performance of most usual activities of everyday life is used. A video film synchronised with the Physilog is obtained for each subject to check the accuracy of the data derived from Physilog. Based on the analysis of the average and the deviation of the acceleration signal, an algorithm is developed to classify the activities in four categories, i.e. lying, sitting, standing and locomotion. Compared with the video observations, the results from the algorithm show an overall misclassification of 10.7%, which is mainly due to confusion between dynamic activities and the standing posture. In contrast, the misclassification between postures is negligible. It is concluded that Physilog can be used in the clinical setting for the reliable measurement and long-term recording of most usual physical activities.
引用
收藏
页码:304 / 308
页数:5
相关论文
共 9 条
[1]  
AMINIAN K, 1995, MED SCI SPORT EXER, V27, P226
[2]   ESTIMATION OF SPEED AND INCLINE OF WALKING USING NEURAL-NETWORK [J].
AMINIAN, K ;
ROBERT, P ;
JEQUIER, E ;
SCHUTZ, Y .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (03) :743-746
[3]   SIMULTANEOUS MEASUREMENT OF HEART-RATE AND BODY MOTION TO QUANTITATE PHYSICAL-ACTIVITY [J].
HASKELL, WL ;
YEE, MC ;
EVANS, A ;
IRBY, PJ .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (01) :109-115
[4]   Differences between patients' and physicians' evaluations of outcome after total hip arthroplasty [J].
Lieberman, JR ;
Dorey, F ;
Shekelle, P ;
Schumacher, L ;
Thomas, BJ ;
Kilgus, DJ ;
Finerman, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (06) :835-838
[5]  
Makikawa M, 1995, MEDINFO 95 P, P747
[6]   Quantitation of lower physical activity in persons with multiple sclerosis [J].
Ng, AV ;
KentBraun, JA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (04) :517-523
[7]   AUTOMATED PHYSICAL-ACTIVITY MONITORING - VALIDATION AND COMPARISON WITH PHYSIOLOGICAL AND SELF-REPORT MEASURES [J].
PATTERSON, SM ;
KRANTZ, DS ;
MONTGOMERY, LC ;
DEUSTER, PA ;
HEDGES, SM ;
NEBEL, LE .
PSYCHOPHYSIOLOGY, 1993, 30 (03) :296-305
[8]  
Sieminski D J, 1997, J Cardiopulm Rehabil, V17, P43, DOI 10.1097/00008483-199701000-00006
[9]  
Veltink P H, 1996, IEEE Trans Rehabil Eng, V4, P375, DOI 10.1109/86.547939