Evaluation of the isotope ratio performance of an axial time-of-flight ICP mass spectrometer

被引:74
作者
Vanhaecke, F
Moens, L
Dams, R
Allen, L
Georgitis, S
机构
[1] Univ Ghent, Inst Nucl Sci, Analyt Chem Lab, B-9000 Ghent, Belgium
[2] LECO Corp, St Joseph, MI 49085 USA
关键词
D O I
10.1021/ac990016b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The isotope ratio performance of an axial time-of-flight ICP mass spectrometer (Renaissance TOF-ICPMS, LECO Corp.) was evaluated. The isotope ratio precision, expressed as the relative standard deviation (RSD) for 10 successive measurements, was evaluated using multielement standard solutions with analyte concentrations of 50-500 mu g/L. The influence of the acquisition time per replicate measurement was studied by varying it between 0.5 and 300 s. For an acquisition time of 30 s per replicate and an elemental concentration of 500 mu g/L, typical isotope ratio precisions of less than or equal to 0.05% RSD were obtained. The fact that this isotope ratio precision can be obtained for many ratios simultaneously is an especially attractive feature of TOF-ICPMS, In contrast to what was expected, increasing the acquisition time per replicate to values of > 30 s resulted in a slightly deteriorated isotope ratio precision. At short acquisition times (< 10 s), isotope ratio precisions similar to, or better than, the best values ever reported for quadrupole-based instruments were obtained. The latter observation remained valid when working with transient signals of corresponding duration. Mass discrimination was observed to be analogous to that observed with other types of ICPMS instrumentation (similar to 1% per mass unit at midmass), The accuracy attainable was evaluated by comparing Pb isotopic results for a "natural" Pb standard solution obtained by TOF-ICPMS with those obtained by thermal ionization mass spectrometry.
引用
收藏
页码:3297 / 3303
页数:7
相关论文
共 63 条
[1]   SAMPLE PREPARATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETERMINATION OF THE ZINC-70 TO ZN-68 ISOTOPE RATIO IN BIOLOGICAL SAMPLES [J].
AMARASIRIWARDENA, CJ ;
KRUSHEVSKA, A ;
FONER, H ;
ARGENTINE, MD ;
BARNES, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :915-921
[2]  
Barnes RM, 1996, FRESEN J ANAL CHEM, V355, P433
[3]   ADVANCES IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - HUMAN-NUTRITION AND TOXICOLOGY [J].
BARNES, RM .
ANALYTICA CHIMICA ACTA, 1993, 283 (01) :115-130
[4]   Ultratrace and precise isotope analysis by double-focusing sector field inductively coupled plasma mass spectrometry [J].
Becker, JS ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1057-1063
[5]   Characterisation and correction of instrumental bias in inductively coupled plasma quadrupole mass spectrometry for accurate measurement of lead isotope ratios [J].
Begley, IS ;
Sharp, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :395-402
[6]  
BENETEAU SB, 1992, ATOM SPECTROSC, V13, P118
[7]   Determination, stable isotope enrichment and kinetics of direct-reacting copper in blood plasma [J].
Buckley, WT ;
Vanderpool, RA ;
Godfrey, DV ;
Johnson, PE .
JOURNAL OF NUTRITIONAL BIOCHEMISTRY, 1996, 7 (09) :488-494
[8]   ACCURATE AND PRECISE DETERMINATION OF LEAD ISOTOPE RATIOS IN CLINICAL AND ENVIRONMENTAL-SAMPLES USING INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY [J].
CAMPBELL, MJ ;
DELVES, HT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (02) :235-236
[9]   ORTHOGONAL ACCELERATION - A NEW DIRECTION FOR TIME-OF-FLIGHT MASS-SPECTROMETRY - FAST, SENSITIVE MASS ANALYSIS FOR CONTINUOUS ION SOURCES [J].
COLES, J ;
GUILHAUS, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (05) :203-213
[10]  
COPLEN TB, IN PRESS PURE APPL C