Dynamic contrast-enhanced MRI quantification of synovium microcirculation in experimental arthritis

被引:11
作者
Doria, AS
Noseworthy, M
Oakden, W
Moineddin, R
Rayner, T
Tassos, V
Engelberts, D
Pritzker, K
Rogers, M
Jong, R
Babyn, P
机构
[1] Hosp Sick Children, Res Inst, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
[3] St Josephs Healthcare, Brain Body Inst, Hamilton, ON, Canada
[4] McMaster Univ, Dept Radiol, Hamilton, ON, Canada
[5] McMaster Univ, Dept Phys Med & Appl Radiat Sci, Hamilton, ON, Canada
[6] Hosp Sick Children, Dept Publ Hlth Family & Community Med, Toronto, ON M5G 1X8, Canada
[7] Mt Sinai Hosp, Dept Pathol & Lab Med, Toronto, ON M5G 1X5, Canada
关键词
animal studies; contrast media; dynamic MRI; pediatric imaging; musculoskeletal imaging; rabbit;
D O I
10.2214/AJR.04.1138
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. Our objective was to analyze MRI contrast-enhancement patterns in arthritic and nonarthritic knees and the relationship of those patterns with clinical, laboratory, and histologic synovium markers. MATERIALS AND METHODS. Dynamic contrast-enhanced MRI was performed in nine arthritic and three nonarthritic knees of juvenile rabbits. A two-compartment pharmacokinetic model of signal intensity-time data was implemented to generate parametric maps of signal slope, maximal percentage of signal change, capillary permeability, leakage space volume, and time-to-peak. MRI values were compared with clinical, laboratory, and histologic markers for evaluation of synovial changes during the progression of arthritis. RESULTS. Parametric maps of capillary permeability and signal slope depicted significant differences between arthritic and nonarthritic knees. Arthritic Knees showed increased capillary permeability (p = 0.006) and signal slope (p = 0.01) with time after onset of disease as opposed to nonarthritic knees (permeability, p = 0.65; slope, p = 0.56). Significant correlations were found between temporal changes in capillary permeability (p = 0.002), signal slope (p = 0.003), and serum concentrations of amyloid A. No relationship was noted between an), MRI parameters and histologic scores. The discriminative power of MRI indexes varied according to the stage of arthritis: time-to-peak was most accurate for differentiation of presence versus absence of arthritis in early arthritis (day 1, p = 0.0002), and signal slope was most accurate in midterm arthritis (day 14, p = 0.001). CONCLUSION. In vivo capillary permeability and signal slope have distinctive dynamic MRI properties. The accuracy of MRI parameters for diagnostic evaluation of experimental arthritis differs according to the stage of disease.
引用
收藏
页码:1165 / 1171
页数:7
相关论文
共 47 条
[1]
ACKERLEY CA, 2002, MICROSC MICROANAL, V8, P456
[2]
Bhujwalla Z M, 1999, Top Magn Reson Imaging, V10, P92, DOI 10.1097/00002142-199904000-00002
[3]
In vivo monitoring of tumor angiogenesis with MR imaging [J].
Brasch, RC ;
Li, KCP ;
Husband, JE ;
Keogan, MT ;
Neeman, M ;
Padhani, AR ;
Shames, D ;
Turetschek, K .
ACADEMIC RADIOLOGY, 2000, 7 (10) :812-823
[4]
Breast lesions: Correlation of contrast medium enhancement patterns on MR images with histopathologic findings and tumor angiogenesis [J].
Buadu, LD ;
Murakami, J ;
Murayama, S ;
Hashiguchi, N ;
Sakai, S ;
Masuda, K ;
Toyoshima, S ;
Kuroki, S ;
Ohno, S .
RADIOLOGY, 1996, 200 (03) :639-649
[5]
Ceponis A, 2001, ARTHRITIS RHEUM, V44, P1908
[6]
Functional tumor imaging with dynamic contrast-enhanced magnetic resonance imaging [J].
Choyke, PL ;
Dwyer, AJ ;
Knopp, MV .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) :509-520
[7]
COOKE TDV, 1988, HDB ANIMAL MODELS RH, V1, P53
[8]
Correlation of dynamic contrast-enhanced MR imaging with histologic tumor grade: Comparison of macromolecular and small-molecular contrast media [J].
Daldrup, H ;
Shames, DM ;
Wendland, M ;
Okuhata, Y ;
Link, TM ;
Rosenau, W ;
Lu, Y ;
Brasch, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :941-949
[9]
COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[10]
The vesiculo-vacuolar organelle (VVO): A distinct endothelial cell structure that provides a transcellular pathway for macromolecular extravasation [J].
Dvorak, AM ;
Kohn, S ;
Morgan, ES ;
Fox, P ;
Nagy, JA ;
Dvorak, HF .
JOURNAL OF LEUKOCYTE BIOLOGY, 1996, 59 (01) :100-115