Oxidative metabolism at the transplanted human heart assessed by positron emission tomography using C-11 acetate

被引:11
作者
Bengel, FM
Ueberfuhr, P
Nekolla, S
Ziegler, SI
Reichart, B
Schwaiger, M
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Nukl Med Klin & Poliklin, D-81675 Munich, Germany
[2] Univ Munich, Herzgefasschirurg Klin, Munich, Germany
关键词
D O I
10.1016/S0002-9149(99)00134-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For investigation of the metabolic profile of the transplanted human heart, positron emission tomography with C-ll acetate was performed to compare global and regional oxidative metabolism in 14 transplant patients with that in 10 healthy volunteers. Because no difference between transplants and normals could be observed, the results suggest that oxidative metabolism remains stable after transplantation, whereas cardiac work remains the major determinant.
引用
收藏
页码:1503 / +
页数:4
相关论文
共 16 条
  • [1] VALIDATION OF [1-C-11]ACETATE AS A TRACER FOR NONINVASIVE ASSESSMENT OF OXIDATIVE-METABOLISM WITH POSITRON EMISSION TOMOGRAPHY IN NORMAL, ISCHEMIC, POSTISCHEMIC, AND HYPEREMIC CANINE MYOCARDIUM
    ARMBRECHT, JJ
    BUXTON, DB
    SCHELBERT, HR
    [J]. CIRCULATION, 1990, 81 (05) : 1594 - 1605
  • [2] Bengel F, 1998, J NUCL MED, V39, p161P
  • [3] BROWN MA, 1989, J NUCL MED, V30, P187
  • [4] RADIOLABELED ACETATE AS A TRACER OF MYOCARDIAL TRICARBOXYLIC-ACID CYCLE FLUX
    BUXTON, DB
    SCHWAIGER, M
    NGUYEN, A
    PHELPS, ME
    SCHELBERT, HR
    [J]. CIRCULATION RESEARCH, 1988, 63 (03) : 628 - 634
  • [5] Effects of cardiac sympathetic innervation on coronary blood flow
    DiCarli, MF
    Tobes, MC
    Mangner, T
    Levine, AB
    Muzik, O
    Chakroborty, P
    Levine, TB
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (17) : 1208 - 1215
  • [6] GROPLER RJ, 1991, J NUCL MED, V32, P245
  • [7] ASSESSMENT OF MYOCARDIAL OXIDATIVE-METABOLISM IN AORTIC-VALVE DISEASE USING POSITRON EMISSION TOMOGRAPHY WITH C-11 ACETATE
    HICKS, RJ
    SAVAS, V
    CURRIE, PJ
    KALFF, V
    STARLING, M
    BERGIN, P
    KIRSCH, M
    SCHWAIGER, M
    [J]. AMERICAN HEART JOURNAL, 1992, 123 (03) : 653 - 664
  • [8] USE OF C-11 ACETATE AND DYNAMIC POSITRON EMISSION TOMOGRAPHY TO ASSESS REGIONAL MYOCARDIAL OXYGEN-CONSUMPTION IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION RECEIVING THROMBOLYSIS OR CORONARY ANGIOPLASTY
    KALFF, V
    HICKS, RJ
    HUTCHINS, G
    TOPOL, E
    SCHWAIGER, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (07) : 529 - 535
  • [9] KAYE DM, 1993, CIRCULATION, V88, P110
  • [10] Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography
    Nekolla, SG
    Miethaner, C
    Nguyen, N
    Ziegler, SI
    Schwaiger, M
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (09) : 1313 - 1321