The Silent Loss of Neuronavigation Accuracy: A Systematic Retrospective Analysis of Factors Influencing the Mismatch of Frameless Stereotactic Systems in Cranial Neurosurgery

被引:119
作者
Stieglitz, Lennart Henning [1 ]
Fichtner, Jens [1 ]
Andres, Robert [1 ]
Schucht, Philippe [1 ]
Kraehenbuehl, Ann-Kathrin [1 ]
Raabe, Andreas [1 ]
Beck, Juergen [1 ]
机构
[1] Univ Hosp Bern, Dept Neurosurg, CH-3010 Bern, Switzerland
关键词
Accuracy; Frameless stereotaxy; Neuronavigation; PATIENT REGISTRATION; IMAGE REGISTRATION; CLINICAL-USE; SURGERY; NAVIGATION;
D O I
10.1227/NEU.0b013e318287072d
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND: Neuronavigation has become an intrinsic part of preoperative surgical planning and surgical procedures. However, many surgeons have the impression that accuracy decreases during surgery. OBJECTIVE: To quantify the decrease of neuronavigation accuracy and identify possible origins, we performed a retrospective quality-control study. METHODS: Between April and July 2011, a neuronavigation system was used in conjunction with a specially prepared head holder in 55 consecutive patients. Two different neuronavigation systems were investigated separately. Coregistration was performed with laser-surface matching, paired-point matching using skin fiducials, anatomic landmarks, or bone screws. The initial target registration error (TRE1) was measured using the nasion as the anatomic landmark. Then, after draping and during surgery, the accuracy was checked at predefined procedural landmark steps (Mayfield measurement point and bone measurement point), and deviations were recorded. RESULTS: After initial coregistration, the mean (SD) TRE1 was 2.9 (3.3) mm. The TRE1 was significantly dependent on patient positioning, lesion localization, type of neuroimaging, and coregistration method. The following procedures decreased neuronavigation accuracy: attachment of surgical drapes (DTRE2 = 2.7 [1.7] mm), skin retractor attachment (DTRE3 = 1.2 [1.0] mm), craniotomy (DTRE3 = 1.0 [1.4] mm), and Halo ring installation (DTRE3 = 0.5 [0.5] mm). Surgery duration was a significant factor also; the overall DTRE was 1.3 [1.5] mm after 30 minutes and increased to 4.4 [1.8] mm after 5.5 hours of surgery. CONCLUSION: After registration, there is an ongoing loss of neuronavigation accuracy. The major factors were draping, attachment of skin retractors, and duration of surgery. Surgeons should be aware of this silent loss of accuracy when using neuronavigation.
引用
收藏
页码:796 / 807
页数:12
相关论文
共 29 条
[1]
[Anonymous], NEUROSURGERY
[2]
Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation [J].
Bjartmarz, Hjalmar ;
Rehncrona, Stig .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2007, 85 (05) :235-242
[3]
An experimental approach to image guided skull base surgery employing a microscope-based neuronavigation system [J].
Brinker, T ;
Arango, G ;
Kaminsky, J ;
Samii, A ;
Thorns, U ;
Vorkapic, P ;
Samii, M .
ACTA NEUROCHIRURGICA, 1998, 140 (09) :883-889
[4]
Neuronavigation: geneology, reality, and prospects [J].
Enchev, Yavor .
NEUROSURGICAL FOCUS, 2009, 27 (03) :E11.1-E11.18
[5]
Two-dimensional high-end ultrasound imaging compared to intraoperative MRI during resection of low-grade gliomas [J].
Gerganov, Venelin M. ;
Samii, Amir ;
Giordano, Mario ;
Samii, Madjid ;
Fahlbusch, Rudolf .
JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (05) :669-673
[6]
Clinical use of the optical digitizer for intracranial neuronavigation [J].
Germane, IM ;
Villalobos, H ;
Silvers, A ;
Post, KD .
NEUROSURGERY, 1999, 45 (02) :261-269
[7]
CLINICAL USE OF A FRAMELESS STEREOTAXIC ARM - RESULTS OF 325 CASES [J].
GOLFINOS, JG ;
FITZPATRICK, BC ;
SMITH, LR ;
SPETZLER, RF .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :197-205
[8]
BrainLab VectorVision neuronavigation system: Technology and clinical experiences in 131 cases [J].
Gumprecht, HK ;
Widenka, DC ;
Lumenta, CB .
NEUROSURGERY, 1999, 44 (01) :97-104
[9]
Intraoperative guidance in maxillofacial and craniofacial surgery [J].
Hassfeld, S ;
Muehling, J ;
Wirtz, CR ;
Knauth, M ;
Lutze, T ;
Schulz, HJ .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (04) :277-283
[10]
Strategies for brain shift evaluation [J].
Hastreiter, P ;
Rezk-Salama, C ;
Soza, G ;
Bauer, M ;
Greiner, G ;
Fahlbusch, R ;
Ganslandt, O ;
Nimsky, C .
MEDICAL IMAGE ANALYSIS, 2004, 8 (04) :447-464