Intraoperative bacterial contamination in operations for joint replacement

被引:161
作者
Davis, N [1 ]
Curry, A [1 ]
Gambhir, AK [1 ]
Panigrahi, H [1 ]
Walker, CRC [1 ]
Wilkins, EGL [1 ]
Worsley, MA [1 ]
Kay, PR [1 ]
机构
[1] Univ Manchester, N Manchester Gen Hosp, Bone Infect Grp, Manchester M8 6RL, Lancs, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1999年 / 81B卷 / 05期
关键词
D O I
10.1302/0301-620X.81B5.9545
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated, Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia, Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant, These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 17 条
[1]   Air contamination during skin preparation and draping in joint replacement surgery [J].
Brown, AR ;
Taylor, GJS ;
Gregg, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01) :92-94
[2]   STERILE-AIR OPERATING THEATRE ENCLOSURE [J].
CHARNLEY, J .
BRITISH JOURNAL OF SURGERY, 1964, 51 (03) :195-&
[3]   THE CONTAMINATED SKIN-KNIFE - A SURGICAL MYTH [J].
FAIRCLOUGH, JA ;
MACKIE, IG ;
MINTOWTCZYZ, W ;
PHILLIPS, GE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (02) :210-210
[4]  
FITZGERALD RH, 1979, ARCH SURG-CHICAGO, V114, P803
[5]  
GRABE N, 1985, J HOSP INFECT, V6, P252, DOI 10.1016/0195-6701(85)90027-1
[6]   AN INVESTIGATION INTO CONTAMINATION OF OPERATIVE SUCTION [J].
GREENOUGH, CG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (01) :151-153
[7]  
HAERI GB, 1980, CLIN ORTHOP RELAT R, P163
[8]  
HOWORTH FH, 1985, LANCET, V1, P386
[9]  
LEARMONTH ID, 1993, ORTHOP CLIN N AM, V24, P735
[10]   ULTRACLEAN AIR AND ANTIBIOTICS FOR PREVENTION OF POSTOPERATIVE INFECTION - A MULTICENTER STUDY OF 8,052 JOINT REPLACEMENT OPERATIONS [J].
LIDWELL, OM ;
ELSON, RA ;
LOWBURY, EJL ;
WHYTE, W ;
BLOWERS, R ;
STANLEY, SJ ;
LOWE, D .
ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (01) :4-13