Tumour detection rate of a new commercially available computer-aided detection system

被引:56
作者
Malich, A
Marx, C
Facius, M
Boehm, T
Fleck, M
Kaiser, WA
机构
[1] Univ Jena, Inst Diagnost & Intervent Radiol, D-07740 Jena, Germany
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8032 Zurich, Switzerland
关键词
computer-aided detection; breast; neoplasms; mammography;
D O I
10.1007/s003300101079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine the tumour detection rate and false positive rate of a new mammographic computer-aided detection system (CAD) in order to assess its clinical usefulness. The craniocaudal and oblique images of 150 suspicious mammograms from 150 patients that were histologically proven to be malignant were analysed using the Second Look CAD (CADx Medical Systems, Quebec, Canada). Cases were selected randomly using the clinic's internal tumour case sampler. Correct marking of the malignant lesion in at least one view was scored as a true positive. Marks not at the location of the malignant lesion were scored as false positives. In addition, mammograms with histologically proven benign masses (n = 50) and microcalcifications (n = 50), as well as 100 non-suspicious mammograms. were scanned in order to determine the value of false-positive marks per image. The 150 mammograms included 94 lesions that were suspicious due to masses, 26 due to microcalcifications and 30 showed both signs of malignancy. The overall sensitivity was 90.0% (135 of 150). Sensitivity on subsets of the data was 88.7% (110 of 124) for suspicious masses (MA) and 98.2% (55 of 56) for microcalcifications. Eight of 14 false-negative cases were large lesions. The overall false-positive rate was observed as 0.28 and 0.97 marks per image of microcalcifications and masses, respectively. The lowest false-positive rates for microcalcifications and MA were observed in the cancer subgroup, whereas the highest false-positive rates were scored in the benign but mammographically suspicious subgroups, respectively. The new CAD system shows a high tumour detection rate, with approximately 1.3 false positive marks per image. These results suggest that this system might be clinically useful as a second reader of mammograms. The system performance was particularly useful for detecting microcalcifications.
引用
收藏
页码:2454 / 2459
页数:6
相关论文
共 30 条
[1]  
*AM CANC SOC, 2000, BREAST CANC FACTS FI
[2]  
*AM CANC SOC, 1996, BREAST CANC FACTS FI
[3]   PROFESSIONAL QUALITY ASSURANCE FOR MAMMOGRAPHY SCREENING PROGRAMS [J].
BIRD, RE .
RADIOLOGY, 1990, 177 (02) :587-587
[4]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[5]   IMPROVEMENT IN RADIOLOGISTS DETECTION OF CLUSTERED MICROCALCIFICATIONS ON MAMMOGRAMS - THE POTENTIAL OF COMPUTER-AIDED DIAGNOSIS [J].
CHAN, HP ;
DOI, K ;
VYBORNY, CJ ;
SCHMIDT, RA ;
METZ, CE ;
LAM, KL ;
OGURA, T ;
WU, YZ ;
MACMAHON, H .
INVESTIGATIVE RADIOLOGY, 1990, 25 (10) :1102-1110
[6]   Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: An ROC study [J].
Chan, HP ;
Sahiner, B ;
Helvie, MA ;
Petrick, N ;
Roubidoux, MA ;
Wilson, TE ;
Adler, DD ;
Paramagul, C ;
Newman, JS ;
Sanjay-Gopal, S .
RADIOLOGY, 1999, 212 (03) :817-827
[7]   Robustness of computerized identification of masses in digitized mammograms - A preliminary assessment [J].
Chang, YH ;
Zheng, B ;
Gur, D .
INVESTIGATIVE RADIOLOGY, 1996, 31 (09) :563-568
[8]   Computer-aided detection of clustered microcalcifications on digitized mammograms: A robustness experiment [J].
Chang, YH ;
Zheng, B ;
Gur, D .
ACADEMIC RADIOLOGY, 1997, 4 (06) :415-418
[9]   Computer-aided diagnosis in radiology: potential and pitfalls [J].
Doi, K ;
MacMahon, H ;
Katsuragawa, S ;
Nishikawa, RM ;
Jiang, YL .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) :97-109
[10]  
EHRENSTEIN T, 2000, EUR RADIOL, V117, pS1