Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients

被引:199
作者
Sakka, SG [1 ]
Reinhart, K [1 ]
Meier-Hellmann, A [1 ]
机构
[1] Univ Jena, Dept Anaesthesiol & Intens Care Med, D-07740 Jena, Germany
关键词
cardiac output; critically ill patients; pulmonary artery thermodilution; transpulmonary thermodilution;
D O I
10.1007/s001340050962
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: We studied the agreement between cardiac output measurements via pulmonary artery thermodilution [CO(PA)], regarded as the current clinical gold standard, and aortic transpulmonary thermodilution [CO(AORTA)]. Design: Prospective clinical study. Setting: Surgical intensive care unit of a university hospital. Patients: 37 patients with sepsis or septic shock (n = 34) and subarachnoid haemorrhage (n = 3). Measurements and results: We analysed 449 simultaneous cardiac output measurements. All patients were deeply sedated and mechanically ventilated in a pressure controlled mode. Each patient received a 7.5-F five-lumen pulmonary artery catheter and a 4-F aortic catheter with an integrated thermistor. The thermistors of the two different catheters were connected to one computer system (COLD-Z021, Pulsion Medical Systems, Munich, Germany). Linear regression analysis revealed: CO(AORTA) = 0.96 . CO(PA) + 1.02 (l/min) (r = 0.97, p < 0.0001). CO(AORTA) was consistently higher than CO(PA) with a bias of 0.68 (l/min) and a standard deviation of 0.62 (l/min). Conclusion: Cardiac output derived from aortic transpulmonary thermodilution is suitable for measurement in the intensive care unit. Measurements of CO(AORTA) are consistent with, but slightly higher than, those obtained from pulmonary artery thermodilution.
引用
收藏
页码:843 / 846
页数:4
相关论文
共 10 条
[1]   CONSERVATION OF THERMAL INDICATOR IN LUNG CIRCULATION [J].
ARFORS, K ;
MALMBERG, P ;
PAVEK, K .
CARDIOVASCULAR RESEARCH, 1971, 5 (04) :530-+
[2]   CARDIAC-OUTPUT MEASUREMENT USING FEMORAL-ARTERY THERMODILUTION IN PATIENTS [J].
BOCK, JC ;
BARKER, BC ;
MACKERSIE, RC ;
TRANBAUGH, RF ;
LEWIS, FR .
JOURNAL OF CRITICAL CARE, 1989, 4 (02) :106-111
[3]   RELATIONSHIP BETWEEN CO AND TRANSIT TIMES FOR DYE AND THERMAL INDICATORS IN CENTRAL CIRCULATION [J].
CARLILE, PV ;
BECKETT, RC ;
GRAY, BA .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (04) :1363-1372
[4]   Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function [J].
Godje, O ;
Peyerl, M ;
Seebauer, T ;
Dewald, O ;
Reichart, B .
CHEST, 1998, 113 (04) :1070-1077
[5]   CANNULATION OF BIG ARTERIES IN CRITICALLY ILL PATIENTS [J].
GURMAN, GM ;
KRIEMERMAN, S .
CRITICAL CARE MEDICINE, 1985, 13 (04) :217-220
[6]   Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting [J].
Gust, R ;
Gottschalk, A ;
Bauer, H ;
Bottiger, BW ;
Bohrer, H ;
Martin, E .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1998, 12 (05) :519-522
[7]   THE SLOWING OF SINUS RHYTHM DURING THERMODILUTION CARDIAC-OUTPUT DETERMINATION AND THE EFFECT OF ALTERING INJECTATE TEMPERATURE [J].
HARRIS, AP ;
MILLER, CF ;
BEATTIE, C ;
ROSENFELD, GI ;
ROGERS, MC .
ANESTHESIOLOGY, 1985, 63 (05) :540-541
[8]  
JANSEN JRC, 1986, INTENS CARE MED, V12, P71
[9]   THE MEASUREMENT OF EXTRA-VASCULAR LUNG WATER BY THERMAL-GREEN DYE INDICATOR DILUTION [J].
LEWIS, FR ;
ELINGS, VB ;
HILL, SL ;
CHRISTENSEN, JM .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1982, 384 (MAY) :394-410
[10]  
WICKERTS CJ, 1990, INTENS CARE MED, V16, P115, DOI 10.1007/BF02575305