Bone repair using a new injectable self-crosslinkable bone substitute

被引:80
作者
Fellah, BH
Weiss, P
Gauthier, O
Rouillon, T
Pilet, P
Daculsi, G
Layrolle, P
机构
[1] INSERM, U791, Fac Dent Surg, F-44042 Nantes, France
[2] Natl Vet Sch Nantes, F-44307 Nantes, France
[3] CHU Nantes, Dept Imagery & Microscopy, RIO IFR26, F-44042 Nantes, France
关键词
bone ingrowth; injectable; biphasic calcium phosphate; hydroxypropyl-methyl cellulose; hydrogel;
D O I
10.1002/jor.20125
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Anew injectable and self-crosslinkable bone substitute (IBS2) was developed for filling bone defects. The IBS2 consisted of a chemically modified polymer solution mixed with biphasic calcium phosphate (BCP) ceramic particles. The polymer hydroxypropylmethyl cellulose was functionalized with silanol groups (Si-HPMC) and formed a viscous solution (3 wt %) in alkaline medium. With a decrease in pH, self-hardening occurred due to the formation of intermolecular -Si-O- bonds. During setting, BCP particles, 40 to 80 pin in diameter, were added to the polymer solution at a weight ratio of 50/50. The resulting injectable material was bilaterally implanted into critically sized bone defects at the distal femoral epiphyses of nine New Zealand White rabbits. The IBS2 filled the bone defects entirely and remained in place. After 8 weeks, bone had grown centripetally and progressed towards the center of the defects. Newly formed bone, ceramic, and nonmineralized tissue ratios were 24.6%+/- 5.6%, 21.6%+/- 5.8%, and. 53.7%+/- 0.1%, respectively. Mineralized and mature bone was observed between and in contact with the BCP particles. The bone/ ceramic apposition was 73.4%+/- 10.6%. The yield strength for the IBS2-filled defects was 16.4 +/- 7.2 MPa, significantly higher than for the host trabecular bone tissue (2.7 +/- 0.4 MPa). This study showed that BCP particles supported the bone healing process by osteoconduction while the Si-HPMC hydrogel created intergranular space for bone ingrowth. This new injectable and self-crosslinkable bone substitute could be used conveniently in orthopedic surgery for filling critical-size bone defects. (c) 2006 Orthopaedic Research Society.
引用
收藏
页码:628 / 635
页数:8
相关论文
共 48 条
  • [1] Computed tomography assessment of alveolar filling with an injectable bone substitute
    Bodic, F
    Amouriq, Y
    Gauthier, O
    Gayet-Delacroix, M
    Bouler, JM
    Daculsi, G
    Hamel, L
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (10) : 953 - 958
  • [2] General properties of silated hydroxyethylcellulose for potential biomedical applications
    Bourges, X
    Weiss, P
    Coudreuse, A
    Daculsi, G
    Legeay, G
    [J]. BIOPOLYMERS, 2002, 63 (04) : 232 - 238
  • [3] Synthesis and general properties of silated-hydroxypropyl methylcellulose in prospect of biomedical use
    Bourges, X
    Weiss, P
    Daculsi, G
    Legeay, G
    [J]. ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2002, 99 (03) : 215 - 228
  • [4] Interaction between hydroxypropyl methylcellulose and biphasic calcium phosphate after steam sterilisation: Capillary gas chromatography studies
    Bourges, X
    Schmitt, M
    Amouriq, Y
    Daculsi, G
    Legeay, G
    Weiss, P
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2001, 12 (06) : 573 - 579
  • [5] FORMATION OF CARBONATE-APATITE CRYSTALS AFTER IMPLANTATION OF CALCIUM-PHOSPHATE CERAMICS
    DACULSI, G
    LEGEROS, RZ
    HEUGHEBAERT, M
    BARBIEUX, I
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1990, 46 (01) : 20 - 27
  • [6] Biphasic calcium phosphate concept applied to artificial bone, implant coating and injectable bone substitute
    Daculsi, G
    [J]. BIOMATERIALS, 1998, 19 (16) : 1473 - 1478
  • [7] Daculsi G, 2000, J BIOMED MATER RES, V50, P1, DOI 10.1002/(SICI)1097-4636(200004)50:1<1::AID-JBM1>3.0.CO
  • [8] 2-W
  • [9] MACROPOROUS CALCIUM-PHOSPHATE CERAMIC FOR LONG-BONE SURGERY IN HUMANS AND DOGS - CLINICAL AND HISTOLOGICAL STUDY
    DACULSI, G
    PASSUTI, N
    MARTIN, S
    DEUDON, C
    LEGEROS, RZ
    RAHER, S
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (03): : 379 - 396
  • [10] DACULSI G, 1995, Patent No. 9521634