The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation

被引:135
作者
Gao, N. P. [1 ]
Niu, J. L. [1 ]
Perino, M. [2 ]
Heiselberg, P. [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
[2] Politecn Torino, DENER, I-10129 Turin, Italy
[3] Aalborg Univ, Hybrid Ventilat Ctr, DK-9000 Aalborg, Denmark
关键词
airborne transmission; high-rise residential buildings; cascade effect; tracer gas; computational fluid dynamics (CFD);
D O I
10.1016/j.buildenv.2007.10.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Airborne transmission of infectious respiratory diseases in indoor environments has drawn our attention for decades, and this issue is revitalized with the outbreak of severe acute respiratory syndrome (SARS). One of the concerns is that there may be multiple transmission routes across households in high-rise residential buildings, one of which is the natural ventilative airflow through open windows between flats, caused by buoyancy effects. Our early on-site measurement using tracer gases confirmed qualitatively and quantitatively that the re-entry of the exhaust-polluted air from the window of the lower floor into the adjacent upper floor is a fact. This study presents the modeling of this cascade effect using computational fluid dynamics (CFD) technique. It is found that the presence of the pollutants generated in the lower floor is generally lower in the immediate upper floor by two orders of magnitude, but the risk of infection calculated by the Wells-Riley equation is only around one order of magnitude lower. It is found that, with single-side open-window conditions, wind blowing perpendicularly to the building may either reinforce or suppress the upward transport, depending on the wind speed. High-speed winds can restrain the convective transfer of heat and mass between flats, functioning like an air curtain. Despite the complexities of the air flow involved, it is clear that this transmission route should be taken into account in infection control. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1805 / 1817
页数:13
相关论文
共 31 条
[1]  
ALLARD F., 1998, Natural ventilation in buildings: a design handbook
[2]   Design analysis of single-sided natural ventilation [J].
Allocca, C ;
Chen, QY ;
Glicksman, LR .
ENERGY AND BUILDINGS, 2003, 35 (08) :785-795
[3]   The airborne transmission of infection in hospital buildings: Fact or fiction? [J].
Beggs, CB .
INDOOR AND BUILT ENVIRONMENT, 2003, 12 (1-2) :9-18
[4]  
*BRIT STAND I, 1980, 5925 BS BRIT STAND I
[5]  
Cheesewright R., 1986, P ASME M HTD, V60, P75
[6]   Prediction of room air motion by Reynolds-Stress models [J].
Chen, Q .
BUILDING AND ENVIRONMENT, 1996, 31 (03) :233-244
[7]  
CHEN Q, 1990, ASHRAE TRAN, V96, P564
[8]  
DAVIES GMJ, 1992, P ROOMVENT 92 3 INT, P419
[9]   Natural ventilation for the prevention of airborne contagion [J].
Escombe, A. Roderick ;
Oeser, Clarissa C. ;
Gilman, Robert H. ;
Navincopa, Marcos ;
Ticona, Eduardo ;
Pan, William ;
Martinez, Carlos ;
Chacaltana, Jesus ;
Rodriguez, Richard ;
Moore, David A. J. ;
Friedland, Jon S. ;
Evans, Carlton A. .
PLOS MEDICINE, 2007, 4 (02) :309-317
[10]  
Etheridge D., 1996, Building ventilation: theory and measurement