Flow cytometry histograms: Transformations, resolution, and display

被引:23
作者
Novo, David [1 ]
Wood, James [2 ]
机构
[1] Do Novo Software, Los Angeles, CA USA
[2] Wake Forest Univ, Sch Med, Dept Canc Biol, Winston Salem, NC 27157 USA
关键词
histogram; data display; transformation; binning; scaling;
D O I
10.1002/cyto.a.20592
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Flow cytometry data analysis routinely includes the use of one- or two-parameter histograms to visualize the data. These histograms have traditionally been plotted with either a linear or logarithmic scale. However, the recent trend of performing the logarithmic conversion in software has made apparent some limitations of the traditional visual presentation of logarithmic data. This review discusses the mathematics of presenting data on a histogram and emphasizes the difference between scaling and binning. The review introduces the concept of an effective resolution to describe how the bin width changes in a variable bin-width histogram. The change in effective resolution is used,to explain the commonly observed valley and picket fencing artifacts. These result from the effective resolution of the display histogram being too high for the data being presented. Recently, several different binning transformations have been described that are becoming more popular because they allow one to view a large dynamic range of data on a single plot, while allowing the display of negative data values. While each of the transforms is based upon different equations, they all exhibit very similar properties. All of the transforms bin the data logarithmically at high channel values and linearly at low channel values. The linear scaling of the lower channels serves to limit the effective resolution of the histogram, thus minimizing the valley and picket fencing artifacts. The newer transformations are not without their own limitations and recommendations for the appropriate manner of presenting flow cytometry data using these newer transformations are discussed. (c) 2008 international Society for Advancement of Cytometry.
引用
收藏
页码:685 / 692
页数:8
相关论文
共 13 条
[1]
HyperLog - A flexible log-like transform for negative, zero, and positive valued data [J].
Bagwell, CB .
CYTOMETRY PART A, 2005, 64A (01) :34-42
[2]
BATTYE FL, 2005, 2005 ISAC SAM A LATT
[3]
BOAS ML, 1966, MATH METHODS PHYS SC, P695
[4]
Interpreting flow cytometry data: a guide for the perplexed [J].
Herzenberg, Leonore A. ;
Tung, James ;
Moore, Wayne A. ;
Herzenberg, Leonard A. ;
Parks, David R. .
NATURE IMMUNOLOGY, 2006, 7 (07) :681-685
[5]
A new "Logicle" display method avoids deceptive effects of logarithmic scaling for low signals and compensated data [J].
Parks, David R. ;
Roederer, Mario ;
Moore, Wayne A. .
CYTOMETRY PART A, 2006, 69A (06) :541-551
[6]
Roederer M, 2001, CYTOMETRY, V45, P194, DOI 10.1002/1097-0320(20011101)45:3<194::AID-CYTO1163>3.0.CO
[7]
2-C
[8]
OPTIMAL AND DATA-BASED HISTOGRAMS [J].
SCOTT, DW .
BIOMETRIKA, 1979, 66 (03) :605-610
[9]
SHAPIRO HM, 2003, PRACTICAL FLOW CYTOM, P35
[10]
Wood JCS, 2004, CYTOM PART A, V59A, P88