Calibration of gamma-ray spectrometers coupled to Compton suppression and fast pneumatic systems for the k0-standardized NAA method

被引:8
作者
Dung, H. M. [1 ]
Freitas, M. C. [1 ]
Sarmento, S. [1 ]
Blaauw, M. [2 ]
Beasley, D. [1 ]
机构
[1] Inst Technol & Nucl, P-2686953 Sacavem, Portugal
[2] Reactor Inst Delft, NL-2629 JB Delft, Netherlands
关键词
D O I
10.1007/s10967-008-1204-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new Compton suppression system (CSS) for the gamma-ray spectrometer portion of the neutron activation analysis (NAA) was set up at the RPI/ITN. The pneumatic transfer system, SIPRA, for short-lived nuclides and cyclic irradiations was improved. A full calibration procedure of the CSS and SIPRA systems was performed. Two certified reference materials, NIST-SRM-1572 (Citrus Leaves) and NIST-SRM-1633a (Coal Fly Ash) were analyzed using the calibration factors. The CSS was instrumental in lowering the detection limits of Cr, Fe, Hg, Rb, Sr, Th and Zn by reducing background and/or spectral interference considerably. The analytical results were evaluated by comparison to the NIST certified values with deviations ranging from 2% to 8% for the above mentioned elements, except Zn ranging from 10% to 15% for biological and environmental samples, respectively.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 8 条
[2]  
De Corte Frans, 1987, The k>0-standardization method
[3]   Fast procedures for coincidence-summing correction in γ-ray spectrometry [J].
De Felice, P ;
Angelini, P ;
Fazio, A ;
Biagini, R .
APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) :745-752
[4]   The application and development of k0-standardization method of neutron activation analysis at Dalat research reactor [J].
Dung, HM ;
Hien, PD .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 257 (03) :643-647
[5]   Use of coincident and non-coincident gamma-rays in Compton suppression neutron activation analysis [J].
Landsberger, S ;
Biegalski, SR ;
O'Kelly, DJ ;
Basunia, MS .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 263 (03) :817-821
[6]   An innovative Compton suppression spectrometer and its capability of evaluation in multi-elemental neutron activation analysis [J].
Lin, X ;
Lierse, C ;
Wahl, W .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (02) :169-178
[7]   The k0-IAEA program [J].
Rossbach, M. ;
Blaauw, M. ;
Bacchi, M. A. ;
Lin, Xilei .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 274 (03) :657-662
[8]   Progress in the ko-IAEA program [J].
Rossbach, Matthias ;
Blaauw, Menno .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (02) :698-701