The classification systems for tibial plateau fractures: How reliable are they?

被引:94
作者
Maripuri, Subramanyam Naidu [1 ]
Rao, Prabhakar [2 ]
Manoj-Thomas, Abraham [1 ]
Mohanty, Khitish [3 ]
机构
[1] Neville Hall Hosp, Abergavenny NP7 7EG, Wales
[2] Wrexham Maelor Hosp, Wrexham LL13 7TD, Wales
[3] Univ Wales Hosp, Cardiff CF14 4XW, S Glam, Wales
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2008年 / 39卷 / 10期
关键词
Tibial plateau fracture classification systems; Reliability of classification systems; Inter and intra-observer reliability;
D O I
10.1016/j.injury.2008.01.023
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Objective: The aim of the study was to assess the inter-observer reliability and intra-observer reproducibility of three different classification systems for tibial plateau fractures. Materials and methods: Four observers of various levels of experience classified 50 tibial plateau fractures. The same observers repeated the classification of the same fractures after an interval of 8 weeks. Inter- and intra-observer variability was assessed using the mean kappa co-efficient and the mean percentage of agreement. Results: For inter-observer reliability, the mean K co-efficient values for Arbeitsgemeinschaft fur Osteosynthesefragen (AO), Schatzker and Hohl and Moore classifications were 0.36, 0.47 and 0.14, respectively. The mean percentage of agreement was 0.52, 0.59 and 0.34, respectively. For intra-observer reliability K-values were 0.80, 0.91 and 0.76 and the mean percentage of agreement was 0.88, 0.93 and 0.85 in the same order. Conclusions: Our results show that none of the classification systems were ideal. The Schatzker classification system was superior to the AO and the Hohl and Moore systems both in terms of inter-observer reliability and intra-observer reproducibility. However, there is a need for developing a more comprehensive approach to judge the classification systems. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1216 / 1221
页数:6
相关论文
共 22 条
[2]
Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures - Results of a multicenter, prospective, randomized clinical trial [J].
McKee M.D. ;
Pirani S.P. ;
Stephen D.J.G. ;
Feibel R. ;
Powell J.N. ;
McCormack R. ;
Schemitsch E.H. ;
Kreder H.J. ;
Sekeramayi F. ;
Zomar M. ;
Wild L.M. ;
Buckley R. ;
Richards R.R. ;
Waddell J.P. ;
Daniels T.R. ;
Bogoch E.R. ;
Finkelstein J. ;
Axelrod T. ;
Perey B. ;
MacPherson H. ;
Goetz T. ;
Pate G. ;
Penner M. ;
Giachino A. ;
Barei D. ;
Veri J.-P. ;
Bulmer B. ;
Conlin L. ;
Elves L. ;
Erho C. ;
Moon K. ;
Kimmel E. ;
Conway A. ;
Hrushowy H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2613-2623
[3]
Arthroscopic-assisted reduction with bilateral buttress plate fixation of complex tibial plateau fractures [J].
Chan, YS ;
Yuan, LJ ;
Hung, SS ;
Wang, CJ ;
Yu, SW ;
Chen, CY ;
Chao, EK ;
Lee, MS .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09) :974-984
[4]
Charalambous CP, 2007, ANN ROY COLL SURG, V89, P400, DOI 10.1308/003588407X187667
[5]
[6]
GARDEN CLASSIFICATION OF FEMORAL-NECK FRACTURES - AN ASSESSMENT OF INTER-OBSERVER VARIATION [J].
FRANDSEN, PA ;
ANDERSEN, E ;
MADSEN, F ;
SKJODT, T .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :588-590
[7]
Hohl M, 1990, Surgery of the musculoskeletal system
[8]
Consistency of AO fracture classification for the distal radius [J].
Kreder, HJ ;
Hanel, DP ;
McKee, M ;
Jupiter, J ;
McGillivary, G ;
Swiontkowski, MF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :726-731
[9]
MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]
Inter-observer reliability and intra-observer reproducibility of the Weber classification of ankle fractures [J].
Malek, I. A. ;
Machani, B. ;
Mevcha, A. M. ;
Hyder, N. H. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (09) :1204-1206