Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle

被引:132
作者
Farina, D
Madeleine, P
Graven-Nielsen, T
Merletti, R
Arendt-Neilsen, L
机构
[1] Politecn Torino, Dept Elect, Ctr Bioingn, I-10129 Turin, Italy
[2] Aalborg Univ, Ctr Sensory Motor Interact, Aalborg, Denmark
关键词
surface electromyography; linear electrode arrays; innervation zone; upper trapezius muscle assessment;
D O I
10.1007/s00421-001-0574-0
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The objectives of this work were to determine optimal surface electromyogram (EMG) electrode locations, and inter-electrode distance (IED), when assessing activity and fatigue in the human upper trapezius muscle. Surface EMG signals were recorded from the upper trapezius muscle of 11 healthy mate subjects using a linear array of 16 surface electrodes. Five arm positions were investigated (arms at the side of the body, 45degrees and 90degrees flexion, 45degrees and 90degrees abduction). Fatiguing (1 kg hand load held for 3 min) and non-fatiguing (no load, 0.5 kg and 1 kg hand load held for 3 s) contractions were made. The variabilities of the average rectified value, root mean square, mean and median power spectral frequency and slope over time of these parameters as functions of electrode location and IED (from 5 mm over a range of 35 min in steps of 5 mm) were quantitatively evaluated. A criterion for selecting the optimal electrode position was applied. This criterion indicated an optimal location measured from the acromion (38% of the distance from the lateral edge of acromion to the spine of the seventh cervical vertebra) which was statistically the same for all the EMG descriptors, arm positions and IED investigated. Finally, it was found that both EMG variables and indexes of muscle fatigue depended on IED which should thus be property standardised. On the basis of the sensitivity or the EMG descriptors to electrode location and crosstalk reduction, an IED of 20 mm is suggested when a global analysis of activity in the upper trapezius muscle is made using a single pair of electrodes. This study emphasises that a surface EMG analysis of the upper trapezius muscle. following a proper placement of the electrodes and selection of IED, can give reliable indications of muscle activity and fatigue. Data on the myoelectric manifestations of muscle fatigue of the upper trapezius muscle are provided for the optimal electrode location.
引用
收藏
页码:469 / 478
页数:10
相关论文
共 48 条
[1]  
Blok J. H., 1997, SENIAM 5 STATE ART S, P60
[2]  
Capodaglio P, 1996, Med Lav, V87, P305
[3]   Self-perceived exertion level and objective evaluation of neuromuscular fatigue in a training session of orchestral violin players [J].
Chan, RFM ;
Chow, CY ;
Lee, GPS ;
To, LK ;
Tsang, XYS ;
Yeung, SS ;
Yeung, EW .
APPLIED ERGONOMICS, 2000, 31 (04) :335-341
[4]  
DIMITROV G V, 1974, Electromyography and Clinical Neurophysiology, V14, P423
[5]   Fundamentals of power spectra of extracellular potentials produced by a skeletal muscle fibre of finite length Part II: Effect of parameters altering with functional state [J].
Dimitrov, GV ;
Dimitrova, NA .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (09) :702-707
[6]  
DIMITROV GV, 1977, AGRESSOLOGIE, V18, P235
[7]   Fundamentals of power spectra of extracellular potentials produced by a skeletal muscle fibre of finite length - Part I: Effect of fibre anatomy [J].
Dimitrov, GV ;
Dimitrova, NA .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (08) :580-587
[8]  
DIMITROVA N, 1974, Electromyography and Clinical Neurophysiology, V14, P53
[9]   Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions [J].
Farina, D ;
Merletti, R .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (05) :337-349
[10]   Compensation of the effect of sub-cutaneous tissue layers on surface EMG: a simulation study [J].
Farina, D ;
Rainoldi, A .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (6-7) :487-497