Parts per million mass accuracy on an orbitrap mass spectrometer via lock mass injection into a C-trap

被引:1242
作者
Olsen, JV
de Godoy, LMF
Li, GQ
Macek, B
Mortensen, P
Pesch, R
Makarov, A
Lange, O
Horning, S
Mann, M
机构
[1] Max Planck Inst Biochem, Dept Proteom & Signal Transduct, D-82512 Martinsried, Germany
[2] Univ So Denmark, CEBI, Dept Biochem & Mol Biol, DK-5230 Odense, Denmark
[3] Chinese Acad Sci, Beijing Inst Genom, Beijing 101300, Peoples R China
[4] Thermo Electron Bremen GmbH, D-28199 Bremen, Germany
关键词
D O I
10.1074/mcp.T500030-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass accuracy is a key parameter of mass spectrometric performance. TOF instruments can reach low parts per million, and FT-ICR instruments are capable of even greater accuracy provided ion numbers are well controlled. Here we demonstrate sub-ppm mass accuracy on a linear ion trap coupled via a radio frequency-only storage trap (C-trap) to the orbitrap mass spectrometer (LTQ Orbitrap). Prior to acquisition of a spectrum, a background ion originating from ambient air is first transferred to the C-trap. Ions forming the MS or MSn spectrum are then added to this species, and all ions are injected into the orbitrap for analysis. Real time recalibration on the "lock mass" by corrections of mass shift removes mass error associated with calibration of the mass scale. The remaining mass error is mainly due to imperfect peaks caused by weak signals and is addressed by averaging the mass measurement over the LC peak, weighted by signal intensity. For peptide database searches in proteomics, we introduce a variable mass tolerance and achieve average absolute mass deviations of 0.48 ppm ( standard deviation 0.38 ppm) and maximal deviations of less than 2 ppm. For tandem mass spectra we demonstrate similarly high mass accuracy and discuss its impact on database searching. High and routine mass accuracy in a compact instrument will dramatically improve certainty of peptide and small molecule identification.
引用
收藏
页码:2010 / 2021
页数:12
相关论文
共 39 条
[1]   A proteomic study of the HUPO Plasma Proteome Project's pilot samples using an accurate mass and time tag strategy [J].
Adkins, JN ;
Monroe, ME ;
Auberry, KJ ;
Shen, YF ;
Jacobs, JM ;
Camp, DG ;
Vitzthum, F ;
Rodland, KD ;
Zangar, RC ;
Smith, RD ;
Pounds, JG .
PROTEOMICS, 2005, 5 (13) :3454-3466
[2]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[3]   Nucleolar proteome dynamics [J].
Andersen, JS ;
Lam, YW ;
Leung, AKL ;
Ong, SE ;
Lyon, CE ;
Lamond, AI ;
Mann, M .
NATURE, 2005, 433 (7021) :77-83
[4]   Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance [J].
Belov, ME ;
Zhang, R ;
Strittmatter, EF ;
Prior, DC ;
Tang, K ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4195-4205
[5]  
CHEN L, 1986, CHEMOMETRICS INTELLI, V1, P51
[6]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[7]   Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR [J].
Easterling, ML ;
Mize, TH ;
Amster, IJ .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :624-632
[8]   Unbiased quantitative proteomics of lipid rafts reveals high specificity for signaling factors [J].
Foster, LJ ;
de Hoog, CL ;
Mann, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (10) :5813-5818
[9]   Quantitative phosphoproteomics applied to the yeast pheromone signaling pathway [J].
Gruhler, A ;
Olsen, JV ;
Mohammed, S ;
Mortensen, P ;
Færgeman, NJ ;
Mann, M ;
Jensen, ON .
MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (03) :310-327
[10]   Interfacing the orbitrap mass analyzer to an electrospray ion source [J].
Hardman, M ;
Makarov, AA .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1699-1705