Controlled Ultrasound-Induced Blood-Brain Barrier Disruption Using Passive Acoustic Emissions Monitoring

被引:153
作者
Arvanitis, Costas D. [1 ]
Livingstone, Margaret S. [2 ]
Vykhodtseva, Natalia [1 ]
McDannold, Nathan [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Neurobiol, Boston, MA 02115 USA
来源
PLOS ONE | 2012年 / 7卷 / 09期
基金
美国国家卫生研究院;
关键词
FOCUSED ULTRASOUND; CAVITATION THRESHOLD; CONTRAST AGENT; MICROBUBBLES; DELIVERY; SINGLE; PROPAGATION; FREQUENCY; COLLAPSE; EFFICACY;
D O I
10.1371/journal.pone.0045783
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The ability of ultrasonically-induced oscillations of circulating microbubbles to permeabilize vascular barriers such as the blood-brain barrier (BBB) holds great promise for noninvasive targeted drug delivery. A major issue has been a lack of control over the procedure to ensure both safe and effective treatment. Here, we evaluated the use of passively-recorded acoustic emissions as a means to achieve this control. An acoustic emissions monitoring system was constructed and integrated into a clinical transcranial MRI-guided focused ultrasound system. Recordings were analyzed using a spectroscopic method that isolates the acoustic emissions caused by the microbubbles during sonication. This analysis characterized and quantified harmonic oscillations that occur when the BBB is disrupted, and broadband emissions that occur when tissue damage occurs. After validating the system's performance in pilot studies that explored a wide range of exposure levels, the measurements were used to control the ultrasound exposure level during transcranial sonications at 104 volumes over 22 weekly sessions in four macaques. We found that increasing the exposure level until a large harmonic emissions signal was observed was an effective means to ensure BBB disruption without broadband emissions. We had a success rate of 96% in inducing BBB disruption as measured by in contrast-enhanced MRI, and we detected broadband emissions in less than 0.2% of the applied bursts. The magnitude of the harmonic emissions signals was significantly (P < 0.001) larger for sonications where BBB disruption was detected, and it correlated with BBB permeabilization as indicated by the magnitude of the MRI signal enhancement after MRI contrast administration (R-2 = 0.78). Overall, the results indicate that harmonic emissions can be a used to control focused ultrasound-induced BBB disruption. These results are promising for clinical translation of this technology.
引用
收藏
页数:16
相关论文
共 51 条
[1]   Collapse and rebound of a laser-induced cavitation bubble [J].
Akhatov, I ;
Lindau, O ;
Topolnikov, A ;
Mettin, R ;
Vakhitova, N ;
Lauterborn, W .
PHYSICS OF FLUIDS, 2001, 13 (10) :2805-2819
[2]  
Arvanitis CD, 2011, P IEEE ULTR IN PRESS
[3]   CAVITATION-ENHANCED EXTRAVASATION FOR DRUG DELIVERY [J].
Arvanitis, Costas D. ;
Bazan-Peregrino, Miriam ;
Rifai, Bassel ;
Seymour, Leonard W. ;
Coussios, Constantin C. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (11) :1838-1852
[4]   CONVECTION-ENHANCED DELIVERY OF MACROMOLECULES IN THE BRAIN [J].
BOBO, RH ;
LASKE, DW ;
AKBASAK, A ;
MORRISON, PF ;
DEDRICK, RL ;
OLDFIELD, EH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (06) :2076-2080
[5]  
Chen H, PHYS REV LETT, V106
[6]   A non-invasive method for focusing ultrasound through the human skull [J].
Clement, GT ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) :1219-1236
[7]   Strategies to improve drug delivery across the blood-brain barrier [J].
de Boer, Albertus G. ;
Gaillard, Pieter J. .
CLINICAL PHARMACOKINETICS, 2007, 46 (07) :553-576
[8]   Ultrasonic characterization of ultrasound contrast agents [J].
de Jong, Nico ;
Emmer, Marcia ;
van Wamel, Annemieke ;
Versluis, Michel .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (08) :861-873
[9]  
Doolittle ND, 2000, CANCER, V88, P637, DOI 10.1002/(SICI)1097-0142(20000201)88:3<637::AID-CNCR22>3.0.CO
[10]  
2-Y