A new self-assembled modified electrode for competitive immunoassay

被引:26
作者
Danilowicz, C [1 ]
Manrique, JM [1 ]
机构
[1] Fac Farm & Bioquim, Dept Quim Analit & Fisicoquim, AR-1113 Buenos Aires, DF, Argentina
关键词
immunoassays; bio-electrodes; multilayers; immunosensors; redox polymers;
D O I
10.1016/S1388-2481(98)00003-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Alternating films constructed upon successive deposition of redox polymer Os(bpy)(2)ClPyCH(2)NHpoly (allylamine) and antibiotin IgG were developed for amperometric immunosensor design. Cyclic voltammetric measurements were used to verify charge transport between redox sites and the redox surface concentration was estimated upon voltammetric peak integration. Biotin-antibiotin complex formation was evaluated using horseradish peroxidase as an enzyme label. Redox mediation between the modified electrode surface and the redox site in the enzyme was verified after substrate addition. Multilayer modified gold electrodes with biologically active antibiotin IgG molecules were employed for the development of a competitive immunoassay with electrochemical label detection. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:22 / 25
页数:4
相关论文
共 13 条
[1]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[2]  
CALVO E, UNPUB
[3]   Assembly of alternating polyelectrolyte and protein multilayer films for immunosensing .2. [J].
Caruso, F ;
Niikura, K ;
Furlong, DN ;
Okahata, Y .
LANGMUIR, 1997, 13 (13) :3427-3433
[4]   Osmium complexes bearing functional groups: building blocks for integrated chemical systems [J].
Danilowicz, C ;
Corton, E ;
Battaglini, F .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 445 (1-2) :89-94
[5]   SEPARATION-FREE SANDWICH ENZYME IMMUNOASSAYS USING MICROPOROUS GOLD ELECTRODES AND SELF-ASSEMBLED MONOLAYER IMMOBILIZED CAPTURE ANTIBODIES [J].
DUAN, CM ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1369-1377
[6]   STRATEGIES FOR ELECTROCHEMICAL IMMUNOASSAY [J].
HEINEMAN, WR ;
HALSALL, HB .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :1321-&
[7]   Strengths and limitations of immunoassays for effective and efficient use for pesticide analysis in water samples: A review [J].
Hennion, MC ;
Barcelo, D .
ANALYTICA CHIMICA ACTA, 1998, 362 (01) :3-34
[8]   Layer-by-layer self-assembly of glucose oxidase with a poly(allylamine)ferrocene redox mediator [J].
Hodak, J ;
Etchenique, R ;
Calvo, EJ ;
Singhal, K ;
Bartlett, PN .
LANGMUIR, 1997, 13 (10) :2708-2716
[9]   APPLICATION OF IMMUNOLOGICAL METHODS FOR THE DETERMINATION OF ENVIRONMENTAL-POLLUTANTS IN HUMAN BIOMONITORING - A REVIEW [J].
KNOPP, D .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :383-392
[10]   Development of an ''electrically wired'' amperometric immunosensor for the determination of biotin based on a non-diffusional redox osmium polymer film containing an antibody to the enzyme label horseradish peroxidase [J].
Lu, B ;
Iwuoha, EI ;
Smyth, MR ;
OKennedy, R .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :59-66