Loop electrosurgical excision procedure for squamous intraepithelial lesions of the cervix: Advantages and potential pitfalls

被引:62
作者
Ferenczy, A
Choukroun, D
Arseneau, J
机构
[1] MCGILL UNIV, DEPT PATHOL, MONTREAL, PQ, CANADA
[2] MCGILL UNIV, DEPT OBSTET & GYNECOL, MONTREAL, PQ, CANADA
[3] ROYAL VICTORIA HOSP, MONTREAL, PQ H3A 1A1, CANADA
关键词
D O I
10.1016/0029-7844(95)00453-X
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To evaluate the advantages and pitfalls of the loop electrosurgical excision procedure as applied to the diagnosis and treatment of cervical cancer precursors. Methods: Loop electrosurgical excision procedure using local anesthesia and colposcopic guidance was performed in an outpatient clinical setting in 1189 consecutive patients referred for colposcopy for an abnormal Papanicolaou smear during a period of 4 years. Results: Of the 1189 patients, 915 (77%) were managed in one sitting with the ''see and treat'' approach, and in 274 patients endocervical curettage and cervical biopsies preceded loop electrosurgical excision procedure. One hundred nineteen (10%) patients were lost to follow-up. Twenty-one patients had either adenocarcinoma in situ (15) or microinvasive squamous cell carcinoma (six) in the loop electrosurgical excision procedure specimen, whereas the electroexcised specimens contained no lesional tissue in 166 (14%) patients. Cure (ie, disease-free at 6 months or longer) was observed in 92% of the 883 evaluable patients after a single treatment and 95% after a repeat loop electrosurgical excision procedure. High-grade squamous intraepithelial lesion was successfully treated with loop electrosurgical excision procedure in 287 (93%) of 309 patients. Complications, mainly intra- and postoperative bleeding, occurred in 7% of the patients. In most loop electrosurgical excision procedure-negative cases, the referral cytologic diagnosis or colposcopy and/or histology were false-positive on review, or the biopsies performed before loop electrosurgical excision procedure removed smaller areas of abnormal tissue. Conclusions: Loop electrosurgical excision procedure using the see and treat approach should be limited to cytologically and colposcopically unequivocal intraepithelial lesions, and depth of excision should be controlled by colposcopy using loop electrodes of appropriate size. In doubtful cases, particularly in the young patient, disease should be ascertained by expert histology and colposcopy before definite therapy. Loop electroexcision represents an attractive means of diagnosing and treating cervical cancer precursors.
引用
收藏
页码:332 / 337
页数:6
相关论文
共 25 条
  • [1] PROSPECTIVE RANDOMIZED TRIAL OF LLETZ VERSUS LASER-ABLATION IN PATIENTS WITH CERVICAL INTRAEPITHELIAL NEOPLASIA
    ALVAREZ, RD
    HELM, CW
    EDWARDS, RP
    NAUMANN, RW
    PARTRIDGE, EE
    SHINGLETON, HM
    MCGEE, JA
    HALL, JB
    HIGGINS, RV
    MALONE, JM
    [J]. GYNECOLOGIC ONCOLOGY, 1994, 52 (02) : 175 - 179
  • [2] CHANGING CHILDBIRTH - COMMENTARY .1.
    ANDERSON, M
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (12): : 1071 - 1072
  • [3] ANDERSON MC, 1986, GYNAECOLOGICAL LASER, P127
  • [5] COLPOSCOPIC DIAGNOSIS AND TREATMENT OF CERVICAL DYSPLASIA AT A SINGLE CLINIC VISIT - EXPERIENCE OF LOW-VOLTAGE DIATHERMY LOOP IN 1000 PATIENTS
    BIGRIGG, MA
    CODLING, BW
    PEARSON, P
    READ, MD
    SWINGLER, GR
    [J]. LANCET, 1990, 336 (8709) : 229 - 231
  • [6] HISTOLOGICAL DIFFERENCES BETWEEN COLPOSCOPIC-DIRECTED BIOPSY AND LOOP EXCISION OF THE TRANSFORMATION ZONE (LETZ) - A CAUSE FOR CONCERN
    CHAPPATTE, OA
    BYRNE, DL
    RAJU, KS
    NAYAGAM, M
    KENNEY, A
    [J]. GYNECOLOGIC ONCOLOGY, 1991, 43 (01) : 46 - 50
  • [7] COEMAN D, 1994, CERVIX, V12, P89
  • [8] THE EFFECT OF CERVICAL LOOP ELECTROSURGICAL EXCISION ON SUBSEQUENT PREGNANCY OUTCOME - NORTH-AMERICAN EXPERIENCE
    FERENCZY, A
    CHOUKROUN, D
    FALCONE, T
    FRANCO, E
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 172 (04) : 1246 - 1250
  • [9] FERENCZY A, 1981, GYNECOL ONCOL, P137
  • [10] LARGE LOOP EXCISION OF THE TRANSFORMATION ZONE (LLETZ) COMPARED TO CARBON-DIOXIDE LASER IN THE TREATMENT OF CIN - A SUPERIOR MODE OF TREATMENT
    GUNASEKERA, PC
    PHIPPS, JH
    LEWIS, BV
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (11): : 995 - 998