Movies of Ice-Embedded Particles Enhance Resolution in Electron Cryo-Microscopy

被引:208
作者
Campbell, Melody G. [5 ]
Cheng, Anchi [5 ]
Brilot, Axel F. [2 ]
Moeller, Arne [5 ]
Lyumkis, Dmitry [5 ]
Veesler, David [5 ]
Pan, Junhua [3 ,4 ]
Harrison, Stephen C. [1 ,3 ,4 ]
Potter, Clinton S. [5 ]
Carragher, Bridget [5 ]
Grigorieff, Nikolaus [1 ,2 ]
机构
[1] Brandeis Univ, Howard Hughes Med Inst, Waltham, MA 02454 USA
[2] Brandeis Univ, Rosenstiel Basic Med Sci Res Ctr, Dept Biochem, Waltham, MA 02454 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
[4] Childrens Hosp, Boston, MA 02115 USA
[5] Scripps Res Inst, Dept Cell Biol, Natl Resource Automated Mol Microscopy, La Jolla, CA 92037 USA
基金
美国国家卫生研究院;
关键词
HOLEY CARBON-FILM; CONFORMATIONAL STATES; ANGSTROM RESOLUTION; SINGLE PARTICLES; PHASE-CONTRAST; ATOMIC MODEL; CRYO-EM; MICROSCOPY; CRYSTALLOGRAPHY; SPECIMENS;
D O I
10.1016/j.str.2012.08.026
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Low-dose images obtained by electron cryo-microscopy (cryo-EM) are often affected by blurring caused by sample motion during electron beam exposure, degrading signal especially at high resolution. We show here that we can align frames of movies, recorded with a direct electron detector during beam exposure of rotavirus double-layered particles, thereby greatly reducing image blurring caused by beam-induced motion and sample stage instabilities. This procedure increases the efficiency of cryo-EM imaging and enhances the resolution obtained in three-dimensional reconstructions of the particle. Using movies in this way is generally applicable to all cryo-EM samples and should also improve the performance of midrange electron microscopes that may have limited mechanical stability and beam coherence.
引用
收藏
页码:1823 / 1828
页数:6
相关论文
共 40 条
[1]   The resolution dependence of optimal exposures in liquid nitrogen temperature electron cryomicroscopy of catalase crystals [J].
Baker, Lindsay A. ;
Smith, Eric A. ;
Bueler, Stephanie A. ;
Rubinstein, John L. .
JOURNAL OF STRUCTURAL BIOLOGY, 2010, 169 (03) :431-437
[2]   Determination of the fold of the core protein of hepatitis B virus ky electron cryomicroscopy [J].
Bottcher, B ;
Wynne, SA ;
Crowther, RA .
NATURE, 1997, 386 (6620) :88-91
[3]   Beam-induced motion of vitrified specimen on holey carbon film [J].
Brilot, Axel F. ;
Chen, James Z. ;
Cheng, Anchi ;
Pan, Junhua ;
Harrison, Stephen C. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Henderson, Richard ;
Grigorieff, Nikolaus .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (03) :630-637
[4]   USE OF SPOT-SCAN PROCEDURE FOR RECORDING LOW-DOSE MICROGRAPHS OF BEAM-SENSITIVE SPECIMENS [J].
BULLOUGH, P ;
HENDERSON, R .
ULTRAMICROSCOPY, 1987, 21 (03) :223-229
[5]   Design of a microfabricated, two-electrode phase-contrast element suitable for electron microscopy [J].
Cambie, Rossana ;
Downing, Kenneth H. ;
Typke, Dieter ;
Glaeser, Robert M. ;
Jin, Jian .
ULTRAMICROSCOPY, 2007, 107 (4-5) :329-339
[6]   Molecular interactions in rotavirus assembly and uncoating seen by high-resolution cryo-EM [J].
Chen, James Z. ;
Settembre, Ethan C. ;
Aoki, Scott T. ;
Zhang, Xing ;
Bellamy, A. Richard ;
Dormitzer, Philip R. ;
Harrison, Stephen C. ;
Grigorieff, Nikolaus .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (26) :10644-10648
[7]   MRC image processing programs [J].
Crowther, RA ;
Henderson, R ;
Smith, JM .
JOURNAL OF STRUCTURAL BIOLOGY, 1996, 116 (01) :9-16
[8]   Transmission electron microscopy with Zernike phase plate [J].
Danev, R ;
Nagayama, K .
ULTRAMICROSCOPY, 2001, 88 (04) :243-252
[9]   Perforated support foils with pre-defined hole size, shape and arrangement [J].
Ermantraut, E ;
Wohlfart, K ;
Tichelaar, W .
ULTRAMICROSCOPY, 1998, 74 (1-2) :75-81
[10]   Review: Electron crystallography: Present excitement, a nod to the past, anticipating the future [J].
Glaeser, RM .
JOURNAL OF STRUCTURAL BIOLOGY, 1999, 128 (01) :3-14