The intra- and interobserver variability of impedance cardiography in patients at rest and during exercise

被引:15
作者
Woltjer, HH
Bogaard, HJ
deVries, PMJM
机构
[1] Department of Pulmonary Medicine, Academic Hospital VU, Amsterdam
关键词
stroke volume; impedance cardiography; variability;
D O I
10.1088/0967-3334/17/3/003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We studied the intra- and interobserver variability in the calculation of stroke volume by the impedance technique, using the recently proposed refinements in the electrode configuration and signal processing. Three groups of patients were included in this study: ten stable cardiac patients who underwent a diagnostic heart catheterization, ten patients 24-26 h after coronary artery bypass surgery and ten patients with severe chronic obstructive pulmonary disease (COPD). The first two groups were studied at rest and the COPD group during sub-maximal exercise. The intra-observer variability was 4.2%, 3.9-4.0% and 6.0-6.9% for the catheterized, surgical and CORD groups, respectively. The interobserver variability was 4.3%, 2.6% and 2.4%, respectively. It is concluded that highly reproducible data can be obtained with the newly proposed impedance technique in patients at rest and exercise which may be comparable or superior to other techniques used in clinical settings.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 31 条
[1]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[2]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[3]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[4]   MEASUREMENT OF CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY UNDER VARIOUS CONDITIONS [J].
BOER, P ;
ROOS, JC ;
GEYSKES, GG ;
DORHOUTMEES, EJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (04) :H491-H496
[5]   MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL IMPEDANCE AT REST AND DURING EXERCISE [J].
DENNISTON, JC ;
MAHER, JT ;
REEVES, JT ;
CRUZ, JC ;
CYMERMAN, A ;
GROVER, RF .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) :91-95
[6]   VARIABILITY OF THORACIC IMPEDANCE CARDIOGRAMS IN MAN [J].
DESOUZA, WM ;
PANERAI, RB .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (04) :411-415
[7]  
DOERR BM, 1981, AVIAT SPACE ENVIR MD, V52, P394
[8]   SPECIFIC RESISTANCE OF BLOOD AT BODY-TEMPERATURE [J].
GEDDES, LA ;
SADLER, C .
MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (03) :336-339
[9]   CLINICAL-EVALUATION OF IMPEDANCE CARDIOGRAPHY [J].
GOLDSTEIN, DS ;
CANNON, RO ;
ZIMLICHMAN, R ;
KEISER, HR .
CLINICAL PHYSIOLOGY, 1986, 6 (03) :235-251
[10]   IMPORTANCE OF BLOOD RESISTIVITY IN MEASUREMENT OF CARDIAC-OUTPUT BY THORACIC IMPEDANCE METHOD [J].
HILL, DW ;
THOMPSON, FD .
MEDICAL & BIOLOGICAL ENGINEERING, 1975, 13 (02) :187-190