Structure-property relationships in polymer composites with micrometer and submicrometer graphite platelets

被引:26
作者
Chasiotis, I [1 ]
Chen, Q
Odegard, GM
Gates, TS
机构
[1] Univ Illinois, Urbana, IL 61801 USA
[2] Michigan Technol Univ, Houghton, MI 49931 USA
[3] NASA, Langley Res Ctr, Durabil Branch, Hampton, VA 23681 USA
基金
美国国家航空航天局;
关键词
polymer composites; graphite platelets; mechanical properties; local properties; nanoindentation;
D O I
10.1177/0014485105059992
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objectives of this work were (a) to investigate the influence of micrometer and submicrometer scale graphite platelets of different aspect ratios and volume fractions on the effective and local quasi-static and dynamic properties of composites with micrometer and submicrometer scale reinforcement, and (b) to compare and evaluate mechanical property measurements of inhomogeneous materials via local (microscale) and bulk (macroscale) experimental methods. Small platelet volume fractions (0.5%) provided proportionally larger increase of the elastic and storage moduli compared to large volume fractions (3.0%). Randomly distributed 15 mu m platelets provided marginally higher composite stiffness compared to 1 mu m platelets while small volume fractions (0.5%) of 15 mu m platelets had a pronounced effect on the effective Poisson's ratio. It was found that local property measurements of inhomogeneous materials conducted by nanoindentation are not representative of the bulk behavior even when the characteristic length of the inhomogeneity is an order of magnitude smaller than the indentation contact area. In this case, statistical averaging of data from a large number of indentations does not result in agreement with bulk measurements. On the other hand, for small aspect ratio platelets with dimensions two orders of magnitude smaller than the nanoindentation contact area, the nanoindenter-obtained properties agreed well with the effective material behavior. It was found that platelets residing at the specimen surface contribute the most to nanoindentation data, which implies that this technique is only valid for well-distributed nanoparticulate and microparticulate systems, and that nanoindentation cannot be used for depth profiling of microstructured composites.
引用
收藏
页码:507 / 516
页数:10
相关论文
共 18 条
  • [1] [Anonymous], 1999, NAN 1999 POL TECHN N
  • [2] CANO RJ, 1992, NASA
  • [3] CHASIOTIS I, 2004, P SOC EXP MECH COST
  • [4] Cheng L, 2000, J POLYM SCI POL PHYS, V38, P10, DOI 10.1002/(SICI)1099-0488(20000101)38:1<10::AID-POLB2>3.0.CO
  • [5] 2-6
  • [6] FUKUSHIMA H, 2001, P 16 ANN AM SOC COMP
  • [7] Li XD, 2002, MATER CHARACT, V48, P11, DOI 10.1016/S1044-5803(02)00192-4
  • [8] LIU C, 2004, P SOC EXP MECH 10 IN
  • [9] Measurement of creep compliance of solid polymers by nanoindentation
    Lu, H
    Wang, B
    Ma, J
    Huang, G
    Viswanathan, H
    [J]. MECHANICS OF TIME-DEPENDENT MATERIALS, 2003, 7 (3-4) : 189 - 207
  • [10] *MTS SYST CORP, 2001, TESTW 4 SOFTW MAN NA