Energy-exergy analysis and modernization suggestions for a combined-cycle power plant

被引:128
作者
Cihan, A [1 ]
Hacihafizoglu, O [1 ]
Kahveci, K [1 ]
机构
[1] Trakya Univ, Muhendislik Mimarlik Fak, Dept Mech Engn, TR-22030 Edirne, Turkey
关键词
exergy; energy; combined-cycle power plant; thermal efficiency; exergy efficiency;
D O I
10.1002/er.1133
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Energy and exergy analysis were carried out for a combined-cycle power plant by using the data taken from its units in operation to analyse a complex energy system more thoroughly and to identify the potential for improving efficiency of the system. In this context, energy and exergy fluxes at the inlet and the exit of the devices in one of the power plant main units as well as the energy and exergy losses Were determined. The results show that combustion chambers, gas turbines and heat recovery steam generators (HRSG) are the main sources of irreversibilities representing more than 85% of the overall exergy losses. Some constructive and thermal suggestions for these devices have been made to improve the efficiency of the system. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 22 条
[1]   Modeling of the high temperature behaviour of IN792 in gas turbine hot parts [J].
Almroth, P ;
Hasselqvist, M ;
Sjöström, S ;
Simonsson, K .
COMPUTATIONAL MATERIALS SCIENCE, 2002, 25 (03) :305-315
[2]  
*BBC, 1986, PERF TESTS GAS TURB
[3]  
BRAM S, 1996, FUEL ENERGY, V37, P210
[4]   Thermoeconomic optimization of heat recovery steam generators operating parameters for combined plants [J].
Casarosa, C ;
Donatini, F ;
Franco, A .
ENERGY, 2004, 29 (03) :389-414
[5]  
Cengel Y.A., 2019, Thermodynamics: An Engineering Approach
[6]   The role of exergy in energy policy making [J].
Dincer, I .
ENERGY POLICY, 2002, 30 (02) :137-149
[7]   Exergy analysis of a solid oxide fuel cell power plant fed by either ethanol or methane [J].
Douvarzides, S ;
Coutelieris, F ;
Tsiakaras, P .
JOURNAL OF POWER SOURCES, 2004, 131 (1-2) :224-230
[8]   Exergy analysis of the semi-closed gas turbine combined cycle (SCGT/CC) [J].
Fiaschi, D ;
Manfrida, G .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (16-18) :1643-1652
[9]   Exergy analysis of a cryogenic hydrogen fuel power plant [J].
Fiaschi, D ;
Manfrida, G .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1999, 24 (08) :731-739
[10]   Combined cycle plant efficiency increase based on the optimization of the heat recovery steam generator operating parameters [J].
Franco, A ;
Russo, A .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (09) :843-859