Evaluation of a photon-counting X-ray imaging system

被引:59
作者
Lundqvist, M [1 ]
Cederström, B
Chmill, V
Danielsson, M
Hasegawa, B
机构
[1] Royal Inst Technol, S-10405 Stockholm, Sweden
[2] Mamea Imaging AB, S-18743 Taby, Sweden
[3] Univ Calif San Francisco, Phys Res Lab, San Francisco, CA 94080 USA
关键词
energy weighting; mammography; photon counting; scanned slit geometry;
D O I
10.1109/23.958392
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A digital imaging system has been developed for mammography using silicon strip detectors operated in a pulse-counting mode and configured in a scanned slit geometry. More than 90% of the photons are absorbed in the sensor. The scatter rejection is very efficient and the image formation is nearly optimal since each X ray is processed individually. The result is a very dose-efficient system. In this paper, we present measurements that verify that the performance of the readout electronics is sufficient to count photons at high rates with high quantum efficiency and a charge collection efficiency that does not limit the dose efficiency. The spatial resolution of the system was measured to provide a modulation transfer function of approximately 0.5 at a spatial frequency of 10 lp/mm. Images of a mammography phantom were recorded experimentally to test overall system performance.
引用
收藏
页码:1530 / 1536
页数:7
相关论文
共 12 条
[1]  
Andersson I, 1997, J Natl Cancer Inst Monogr, P63
[2]  
ARTIFELLI F, 1997, NUCL INSTRUM METH A, V385, P311
[3]  
BARNES G, 1999, RSNA CATEGORICAL COU, P41
[4]   High resolution X-ray imaging using a silicon strip detector [J].
Beuville, E ;
Cahn, R ;
Cederström, B ;
Danielsson, M ;
Hall, A ;
Hasegawa, B ;
Luo, L ;
Lundqvist, M ;
Nygren, D ;
Oltman, E ;
Walton, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :3059-3063
[5]   Detective quantum efficiency dependence on x-ray energy weighting in mammography [J].
Cahn, RN ;
Cederström, B ;
Danielsson, M ;
Hall, A ;
Lundqvist, M ;
Nygren, D .
MEDICAL PHYSICS, 1999, 26 (12) :2680-2683
[6]   Dose-efficient system for digital mammography [J].
Danielsson, M ;
Bornefalk, H ;
Cederström, B ;
Chmill, V ;
Hasegawa, B ;
Lundqvist, M ;
Nygren, D ;
Tabár, T .
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 :239-249
[7]   Computer simulations and performance measurements on a silicon strip detector for edge-on imaging [J].
Lundqvist, M ;
Cederström, B ;
Chmill, V ;
Danielsson, M ;
Nygren, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1487-1492
[8]   SNR AND DQE ANALYSIS OF BROAD-SPECTRUM X-RAY-IMAGING [J].
TAPIOVAARA, MJ ;
WAGNER, RF .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (06) :519-529
[9]   Spectral response of multi-element silicon x-ray detectors [J].
Tull, CR ;
Ludewigt, BA ;
Lewak, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :421-427
[10]  
VACCHI A, 1993, PHYS MEDICA, V9, P155