Flicker Mitigation by Individual Pitch Control of Variable Speed Wind Turbines With DFIG

被引:59
作者
Zhang, Yunqian [1 ,2 ]
Chen, Zhe [1 ]
Hu, Weihao [1 ]
Cheng, Ming [2 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[2] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Flicker; flicker mitigation; individual pitch control (IPC); variable speed wind turbine; EMISSION;
D O I
10.1109/TEC.2013.2294992
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the wind speed variation, wind shear and tower shadow effects, grid connected wind turbines are the sources of power fluctuations which may produce flicker during continuous operation. This paper presents a model of an MW-level variable-speed wind turbine with a doubly fed induction generator to investigate the flicker emission and mitigation issues. An individual pitch control (IPC) strategy is proposed to reduce the flicker emission at different wind speed conditions. The IPC scheme is proposed and the individual pitch controller is designed according to the generator active power and the azimuth angle of the wind turbine. The simulations are performed on the NREL (National Renewable Energy Laboratory) 1.5-MW upwind reference wind turbine model. Simulation results show that damping the generator active power by IPC is an effective means for flicker mitigation of variable speed wind turbines during continuous operation.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 15 条
  • [1] [Anonymous], 1997, 61000415 IEC
  • [2] Further load reductions with individual pitch control
    Bossanyi, EA
    [J]. WIND ENERGY, 2005, 8 (04) : 481 - 485
  • [3] Individual blade pitch control for load reduction
    Bossanyi, EA
    [J]. WIND ENERGY, 2003, 6 (02) : 119 - 128
  • [4] Flicker Mitigation by Active Power Control of Variable-Speed Wind Turbines With Full-Scale Back-to-Back Power Converters
    Hu, Weihao
    Chen, Zhe
    Wang, Yue
    Wang, Zhaoan
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (03) : 640 - 649
  • [5] Jonkman B. J., 2005, NRELEL50038230
  • [6] Mitigation of the Flicker Level of a DFIG Using Power Factor Angle Control
    Kim, Yun-Seong
    Won, Dong-Jun
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) : 2457 - 2458
  • [7] Flicker emission of wind turbines during continuous operation
    Larsson, Å
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (01) : 114 - 118
  • [8] Comparative study on transient stability analysis of wind turbine generator system using different drive train models
    Muyeen, S. M.
    Ali, Md. Hasan
    Takahashi, R.
    Murata, T.
    Tamura, J.
    Tomaki, Y.
    Sakahara, A.
    Sasano, E.
    [J]. IET RENEWABLE POWER GENERATION, 2007, 1 (02) : 131 - 141
  • [9] Papadopoulos MP, 1998, INT C HARMON QUAL PO, P1152, DOI 10.1109/ICHQP.1998.760201
  • [10] Rossetto L., 1999, IEEE Industry Applications Magazine, V5, P34, DOI 10.1109/2943.798335